TrueNAS ES24F Basic Setup

Vereisten en specificaties
We recommend these tools when installing a TrueNAS ES24F in a rack:
- #2 kruiskopschroevendraaier
- Platte schroevendraaier
- Meetlint
- Niveau
| ES24F Specifications | |
| Afmetingen (H x B x L) | 3.5 inch x 19 inch x 20.5 inch (89 mm x 482.6 mm x 520.7 mm) |
| Lengte inclusief chassisrail | 24.3 in (617.22mm) |
| Nettogewicht (volledig geladen) | 50 lbs (23 kg) |
| Bedrijfstemperatuur | 32°F – 95°F (0°C – 35°C) |
| Niet-bedrijfstemperatuur | -4°F – 158°F (-20°C – 70°C) |
| Bedrijfsvochtigheid (niet-condenserend) | 5% – 95% |
| Leveringsvolumetage | 100-127~/7A 50-60 Hz
or 200-240V~,3.5A 50-60 Hz |
Invoering
The TrueNAS ES24F is a 2U expansion shelf with 24 2.5” drive bays, SAS3 (12 Gb/s), dual expansion controllers, and redundant power supplies.
Review the safety considerations and hardware requirements before installing an ES24 into a rack.
Veiligheid
Statische ontlading
Waarschuwing – Elektrostatische ontlading (ESD)
Statische elektriciteit kan zich in uw lichaam ophopen en ontladen wanneer u geleidende materialen aanraakt. Elektrostatische ontlading (ESD) is schadelijk voor gevoelige elektronische apparaten en componenten. Houd deze veiligheidsaanbevelingen in gedachten voordat u de systeembehuizing opent of niet-hot-swappable systeemcomponenten aanraakt.
- Schakel het systeem uit en verwijder de voedingskabels voordat u de behuizing opent of interne componenten aanraakt.
- Plaats het systeem op een schoon, hard werkoppervlak, zoals een houten tafelblad. Gebruik indien mogelijk een ESD-dissipatieve mat om de interne componenten te beschermen.
- Raak het metalen chassis met uw blote hand aan om de statische elektriciteit in uw lichaam af te voeren voordat u interne componenten aanraakt, inclusief componenten die nog niet in het systeem zijn geïnstalleerd. Wij adviseren altijd een antistatisch polsbandje te dragen en een aardingskabel te gebruiken.
- Bewaar alle systeemcomponenten in antistatische zakken.
Omgaan met het systeem
We raden aan dat ten minste twee mensen een TrueNAS-systeem optillen.
Waarschuwing
Probeer nooit een TrueNAS-systeem met schijven erin op te tillen! Installeer het systeem in een rack voordat u schijven toevoegt. Verwijder de schijven voordat u het systeem uit het rack haalt.
Houd het systeem zo mogelijk vanaf de zijkanten of onderkant vast. Houd altijd rekening met losse kabels of connectoren en vermijd het knellen of stoten van deze elementen waar mogelijk.
Dit document gebruikt "links" en "rechts" volgens uw perspectief wanneer u naar de voorkant van een systeem of rack kijkt.

The TrueNAS ES24F is a network storage server intended for use in enterprise and datacenter environments.
Het apparaat is ontworpen om als volgt te worden bediend:
- In gecontroleerde IT-omgevingen, binnen de gespecificeerde bereiken voor temperatuur, luchtvochtigheid en voedingsspanning.tage
- Bij correct geaarde elektrische installaties, in overeenstemming met de plaatselijke elektrische voorschriften.
- In overeenstemming met de TrueNAS-softwaredocumentatie, inclusief configuratie-, bedienings- en onderhoudsinstructies.
Dit product is niet ontworpen voor, en ook niet bedoeld voor:
- Te gebruiken in levensondersteunende systemen of andere veiligheidskritische toepassingen waarbij een storing kan leiden tot letsel of overlijden.
- Use in residential consumer environments, unless explicitly installed and operated in a controlled, non-domestic IT setting.
- Elk gebruik dat buiten de voorwaarden en doeleinden valt die in deze handleiding en de TrueNAS-softwaredocumentatie worden beschreven.
Raadpleeg voor gedetailleerde configuratie- en bedieningsinstructies de TrueNAS-softwaredocumentatie die bij het product is geleverd en die verkrijgbaar is bij TrueNAS.
The ES24F is FCC/CE-marked and complies with:
- FCC 47 CFR Deel 15, Klasse A – Grenswaarden voor uitgestraalde en geleide emissies van commerciële IT-apparatuur (EMI/EMC)
- Laag volumetage Richtlijn (LVD) 2014/35/EU – Elektrische veiligheid
- Richtlijn 2014/30/EU inzake elektromagnetische compatibiliteit (EMC) – Elektromagnetische interferentie en immuniteit
- RoHS-richtlijn 2011/65/EU, zoals gewijzigd door (EU) 2015/863 – Beperking van gevaarlijke stoffen
- WEEE-richtlijn 2012/19/EU – Afval van elektrische en elektronische apparatuur
Voor vragen over regelgeving of naleving kunt u contact opnemen met compliance@truenas.com.
Geautoriseerde vertegenwoordiger van de EU: Obelis S.A. – Boulevard Général Wahis 53, B-1030 Brussels, BELGIUM
Belangrijk – Batterij-informatie
Dit product bevat een lithiumknoopcelbatterij (CMOS-batterij) die wordt gebruikt om de systeeminstellingen te behouden. Gooi de batterij niet bij het huisvuil. Gebruikte batterijen moeten apart worden ingezameld en afgevoerd in overeenstemming met de lokale regelgeving en de EU-batterijrichtlijn 2006/66/EC. Het symbool van de doorgestreepte afvalbak op wielen geeft aan dat de batterij naar een geschikt inzamelpunt voor recycling moet worden gebracht.
ES24F Components
- TrueNAS-eenheden worden zorgvuldig verpakt en verzonden met vertrouwde vervoerders om in perfecte staat aan te komen.
- Als er transportschade is of er onderdelen ontbreken, maak dan foto's en neem onmiddellijk contact op met de TrueNAS-ondersteuning via support@truenas.com, 1-855-GREP4-iX (1-855-473-7449), or 1-408-943-4100.
- Zoek en noteer de serienummers van de hardware op de achterkant van elk chassis voor snelle referentie.
Pak de verzenddozen voorzichtig uit en zoek de volgende onderdelen op:

Knipperlichten voor
The ES24F has buttons/lights for power, alarm mute, locate ID, and fault. The fault light activates during the initial power-on self-test (POST) or when the TrueNAS software generates an alert.

Achtercomponenten en poorten

Rack the System
The ES24F requires an EIA-310 compliant rack. To properly install the rack rails, the vertical rack posts need to be spaced between 23” – 35.75” (584mm-908mm) apart.
Installeer de chassisrails
Each rail has two components, the outer rack rail and the inner chassis rail. To protect it during shipping, the chassis rail is inserted into the rack rail and must be removed before attaching to a system. Slide the chassis rail forward until the metal catch stops it in place. Push in the catch and continue to slide the chassis rail forward until it is free of the rack rail.

Align the chassis rail end stamped “FRONT” with the front of the ES24F. Fit the rail keyholes over the system mounting pegs and slide it into place. Use one of the included short M4 screws to secure the rail to the system.

Repeat this procedure to attach the second chassis rail to the other side of the system.
Installeer de rekrails
- Ensure the rack has enough space for the system. The ES24F needs 2U of space for both the system and rack rails. The rack rails install into the bottom 1U of the reserved space.
- Align the rail end stamped “FRONT” with the front of the rack. Face the “FRONT” text inside the rack so the chassis rails can slide into the rack rails. Align the rail front pegs with the top and bottom holes in the bottom 1U and push the rail into the holes until the spring latch locks the rail in place.
The rail kit includes two optional retention screw hole extenders that you can screw into the middle rail attach point.

After you install the front of the rail, extend the back of the rack rail towards the equivalent attach points on the rear rack post. Make sure the rail remains level from front to back. Repeat this process to install the other rack rail.

Monteer het systeem in het rack
Waarschuwing
The ES24F requires two people to safely lift in and out of a rack. Do not install drives until after you mount the ES24F in the rack. Remove all drives before taking the ES24F out of the rack.
Align the chassis rails with the rack rails. Slide the ends of the chassis rails into the rack rails and push the system forward until the metal safety catches click into place. Squeeze the safety catches against the sides of the system and slide the ES24F into the rack.

De railkit bevat extra M4-schroeven die kunnen worden gebruikt om het systeem aan de rackrails te bevestigen.
Schijven installeren
- TrueNAS-apparaten ondersteunen alleen goedgekeurde harde schijven en SSD's. Neem contact op met het verkoopteam als u meer schijven of vervangingen nodig hebt. Het toevoegen van niet-goedgekeurde schijven aan het systeem maakt de garantie ongeldig. Neem contact op met de ondersteuning als schijven niet correct in de trays zijn geplaatst.
- To insert a drive in a tray, face the drive connectors toward the rear of the tray and align the side screw holes with the tray retention pegs. Push the drive side screw holes into the fixed retention pegs. Then, push the drive into the flexible retention pegs until it clicks.
- To remove a drive, push on the drive from the bottom of the tray to pop it out from the flexible retention pegs.

- If you purchased fewer than 24 drives with the system, the system has air baffles installed in all remaining drive tray slots. To install new drive trays in the system, remove a baffle by inserting a flathead screwdriver in the baffle grooves, then gently push the baffle out. For proper airflow, we recommend you keep all baffles in place unless you are installing new drives.

- Each drive tray has two indicator lights for status and fault. The status light is blue when the drive is active or a hot spare. The fault light is solid red when the drive has an error or an active identify command.
- Press the button on the drive tray to open the latch. Carefully slide the tray into a drive bay until the latch begins to close. Gently push the latch closed until it clicks into place in the chassis.

- To remove a drive tray, press the button to open the latch, then gently swing the latch open and pull the tray out.
Stroomkabels aansluiten
- Sluit de netsnoeren nog niet aan op een stopcontact. Sluit een netsnoer aan op de achterkant van één voeding. Plaats het snoer in de plastic clamp en druk het lipje in de vergrendeling om het op zijn plaats te vergrendelen. Herhaal het proces voor de tweede voeding en snoer.

Program Power Loss Mode
The ES24F can be programmed to automatically restart if the power input has been lost and subsequently restored. By default, if the ES24F loses power, it does not automatically start when power is restored. You must press the power button to turn the system on. However, you can set the ES24F to restart automatically when power is restored to the system.
Om deze modus te activeren, drukt u snel drie keer op de aan/uit-knop.
The power button blinks to indicate the current mode. When it blinks quickly, the system automatically starts when power is restored. When the button blinks slowly, you must manually power on the system after a power loss. To test the current setting, disconnect the power, wait a few moments, and plug the system back in.
Opslaguitbreiding
- Plug the ES24F power cords into power outlets. Wait two minutes for the drives to start.
- To set up SAS between your TrueNAS system and expansion shelves, cable the first port on the first TrueNAS controller to the first port on the first expansion shelf IOM/expander. High
- Availability (HA) systems require another cable from the first port on the second TrueNAS controller to the first port on the second expansion shelf controller.
- Wij raden geen andere bekabelingsconfiguraties aan. Neem contact op met iX Support als u andere bekabelingsmethoden nodig heeft.
- Als uw TrueNAS-systeem HA heeft, start u opnieuw op of failover nadat u SAS-kabels hebt aangesloten om schijven tussen controllers te synchroniseren.
Belangrijk
- Houd u bij het opzetten van SAS-verbindingen aan de bedrading examphieronder.
- Connecting expansion shelves incorrectly causes errors. Never cable a single controller to different expanders on the same shelf.
X-Serie
- X-Series with a single ES24F Expansion Shelf

- X-Series with two ES24F Expansion Shelves

R-serie
R20
- R20 with a single ES24F Expansion Shelf

- R20 with two ES24F Expansion Shelves

R40
- R40 with a single ES24F Expansion Shelf

- R40 with two ES24F Expansion Shelves

M-serie
M40
- M40 with a single ES24F Expansion Shelf

- M40 with two ES24F Expansion Shelves

M50 en M60
- M50/M60 with a single ES24F Expansion Shelf

- M50/M60 with three ES24F Expansion Shelves. The M50 can support up to 8 total Expansion Shelves with the use of additional SAS cards. The M60 can support up to 12 total Expansion Shelves with the use of additional SAS cards.

Aanvullende bronnen
De TrueNAS Documentation Hub heeft volledige softwareconfiguratie en gebruiksinstructies. Klik op Gids in de TrueNAS web interface of ga direct naar: https://www.truenas.com/docs.
- Aanvullende hardwarehandleidingen en artikelen vindt u in de sectie Hardware van de documentatiehub: https://www.truenas.com/docs/hardware.2
- De TrueNAS-forums bieden mogelijkheden om met andere TrueNAS-gebruikers te communiceren en hun configuraties te bespreken: https://forums.truenas.com/3
Contact opnemen met iXsystems
Ondervindt u problemen? Neem dan contact op met de TrueNAS Enterprise-ondersteuning voor een vlotte oplossing.
| Contact methode | Contact Opties |
| Web | https://www.truenas.com/support 4 |
| support@truenas.com | |
| Telefoon | Monday-Friday, 6:00 AM to 6:00 PM Pacific Standard Time:
• Alleen in de VS gratis: 1-855-473-7449 optie 2 • Lokaal en internationaal: 1-408-943-4100 optie 2 |
| Telefoon | Telefoon buiten kantooruren (alleen 24×7 Gold Level-ondersteuning):
• Alleen in de VS gratis: 1-855-499-5131 • Internationaal: 1-408-878-3140 (Internationale beltarieven zijn van toepassing) |
| Adres | iXsystems, Inc. dba TrueNAS – 541 Division St, Campbel, CA 95008, VS |

Documenten / Bronnen
![]() | ES24F Basic Setup |
Referenties
- Gebruiksaanwijzingmanual.tools