ACiQ B0DHFF2DKL

Gebruikershandleiding voor het ACiQ 2.5 Ton 17 SEER2 centrale inverter warmtepompsysteem

Model: B0DHFF2DKL

1. Inleiding

This manual provides essential information for the installation, operation, and maintenance of your ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System. This system is designed to provide efficient heating and cooling for residential and light commercial applications. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and safety.

2. Veiligheidsinformatie

Always prioritize safety. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Consult a qualified installer, service agency, or the gas supplier for information or assistance. The information contained in this manual is intended for use by qualified service personnel only.

  • Elektrische veiligheid: Ensure the power supply is disconnected before performing any service or maintenance. All electrical wiring must comply with local and national electrical codes.
  • Koelmiddelbehandeling: This system uses R-454B refrigerant. Only certified technicians should handle refrigerants.
  • Installatie: Installation must be performed by a licensed HVAC professional.
  • Persoonlijke beschermingsmiddelen: Always wear appropriate personal protective equipment (PPE) such as gloves and safety glasses during installation and maintenance.

3. Belangrijkste kenmerken

  • Omvormertechnologie: Biedt nauwkeurige temperatuurregeling, een lager energieverbruik en een stillere werking.
  • Hoge efficiëntie: 18.8 SEER2 and 9.7 HSPF2 ratings for energy savings.
  • Breed werkingsbereik: Reliable performance from -13°F to 122°F.
  • Stille werking: Indoor noise levels as low as 44 dBA, outdoor unit at 60 dBA.
  • Duurzame componenten: Rotary compressor, aluminum coil, and fiberglass-free insulation.
  • Milieuvriendelijk koelmiddel: Utilizes R-454B refrigerant.
  • Flexibele installatie: Supports horizontal and vertical air handler installation.
  • Slimme bediening: Compatible with wired controllers, WiFi, and third-party thermostats.
  • Integrated Back-up Heat: Includes a 10kW back-up heat kit for supplemental heating.

4. Componenten voorbijview

The ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System includes the following main components:

  • Outdoor Condensing Unit (Heat Pump)
  • Binnenluchtbehandelingsunit
  • 10kW Back-up Heat Kit
  • 30' Line Set
  • Gauge Electrical Whip
  • 60A Non-Fused Disconnect Switch
  • WiFi-thermostaat
  • Surge Protector
  • CPS Charging Adapter
  • Muur mouw
ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System components

Figuur 1: Overview of the ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System, showing the outdoor unit, indoor air handler, 10kW back-up heat kit, thermostat, line set, and various installation accessories.

5. Installatie en installatie

Installation of this ACiQ heat pump system requires specialized knowledge and tools. It must be performed by a qualified and licensed HVAC technician to ensure safety, compliance with local codes, and optimal performance. Refer to the detailed installation manual provided with the product for specific instructions.

5.1 Controles vóór installatie

  • Verify that the electrical supply matches the unit's requirements (Indoor: 115/208/230V, 60Hz, 1Ph; Outdoor: 208/230V, 60Hz, 1Ph).
  • Zorg voor voldoende ruimte voor zowel de binnen- als de buitenunit, zodat er voldoende luchtcirculatie is en onderhoudstoegang mogelijk is.
  • Confirm that the maximum piping length (164 ft / 50m) and height difference (82 ft / 25m) are not exceeded.

5.2 Air Handler Installation

The indoor air handler unit is designed for flexible installation, supporting upflow, downflow, and horizontal configurations to suit various space requirements.

Multi-Positional Air Handler Unit installation options

Figuur 2: Diagram illustrating the multi-positional capabilities of the indoor air handler unit, showing options for upflow, downflow, and horizontal installation.

5.3 Plaatsing van de buitenunit

Consider the outdoor unit's dimensions and required clearances for optimal performance and maintenance. The unit features a compact design compared to traditional systems.

Outdoor unit size comparison with traditional units

Figuur 3: Graphic comparing the smaller footprint of the ACiQ outdoor unit (20 inches clearance) versus a traditional unit (36 inches clearance), highlighting its high efficiency and self-cleaning features.

6. Gebruiksaanwijzing

Your ACiQ heat pump system offers advanced control options for comfortable and efficient operation.

6.1 Basisbedieningsmodi

  • Koelmodus: Provides cooling with a capacity of 31,000 BTU/hr. Operates efficiently from -13°F to 122°F ambient temperatures.
  • Verwarmingsmodus: Provides heating with a capacity of 30,000 BTU/hr at 47°F. Reliable warmth down to -13°F. The 10kW back-up heat kit provides supplemental heat when needed.
  • Ventilator modus: Laat de lucht circuleren zonder te verwarmen of te koelen.
  • Automatische modus: Schakelt automatisch tussen verwarmen en koelen om de ingestelde temperatuur te handhaven.
ACiQ outdoor unit operating in extreme heat

Figuur 4: The ACiQ outdoor unit installed on a patio, demonstrating its ability to operate effectively in extreme heat conditions, up to 122°F.

ACiQ outdoor unit operating in extreme cold

Figuur 5: The ACiQ outdoor unit partially covered in snow, illustrating its capability to operate in extreme cold temperatures, down to -13°F.

6.2 Smart Controls

The system can be controlled via the included wired thermostat, WiFi-enabled app, or compatible third-party thermostats. The WiFi app allows for remote control and monitoring of your system.

ACiQ Smart Home app and wired thermostat

Figuur 6: Image showing the ACiQ Smart Home mobile application interface on a smartphone alongside a wired thermostat, demonstrating the system's smart control capabilities for climate management.

7. Onderhoud

Regular maintenance ensures the longevity and efficiency of your ACiQ heat pump system. Always disconnect power before performing any maintenance.

  • Luchtfilter vervangen: Check and replace air filters in the indoor air handler every 1-3 months, or more frequently if needed. Dirty filters restrict airflow and reduce efficiency.
  • Reiniging van de buitenunit: Keep the outdoor unit free from debris, leaves, and dirt. Periodically clean the coils with a soft brush or water hose (ensure power is off).
  • Drainagesysteem: Ensure the condensate drain line is clear and free of blockages to prevent water overflow.
  • Professionele Inspectie: Schedule annual inspections and maintenance by a qualified HVAC technician.

8. Probleemoplossing

This section provides solutions for common issues. For complex problems, contact a qualified HVAC technician.

  • Geen stroom: Check circuit breakers and ensure the disconnect switch is in the ON position.
  • Onvoldoende verwarming/koeling: Verify thermostat settings, check air filters for blockage, and ensure outdoor unit is not obstructed.
  • Ongebruikelijke geluiden: Minor operational noises are normal. Loud or unusual noises may indicate a problem requiring professional inspection.
  • Waterlekken: Check condensate drain line for blockages.

9. Specificaties

Dimensions of ACiQ indoor and outdoor units

Figuur 7: Image displaying the dimensions of both the indoor air handler unit (49.02" H x 21.02" W x 21.02" D) and the outdoor condensing unit (35.04" H x 37.24" W x 16.14" D).

Cooling capacity chart for ACiQ heat pump

Figuur 8: Chart detailing the cooling capacity of the ACiQ system at various outdoor temperatures: 86°F (118% capacity), 95°F (113% capacity), 110°F (99% capacity), and 122°F (48% capacity).

Heating capacity chart for ACiQ heat pump

Figuur 9: Chart detailing the heating capacity of the ACiQ system at various outdoor temperatures: -22°F (N/A), -13°F (41% capacity), 0°F (57% capacity), 17°F (70% capacity), and 32°F (73% capacity).

FunctieDetail
Koelvermogen31,000 BTU/uur
Verwarmingscapaciteit30,000 BTU/hr (at 47°F)
SEER2-classificatie18.8
HSPF2-classificatie9.7
Koelmiddel TypeR-454B
Voeding binnenunit115/208/230V, 60Hz, 1Ph
Voeding voor buitenunit208/230V, 60Hz, 1Ph
Maximale leidinglengte164 voet (50m)
Max Height Difference82 voet (25m)
Indoor Unit Dimensions (W × D × H)21.02" × 21.02" × 49.02"
Outdoor Unit Dimensions (W × D × H)37.24" × 16.14" × 31.89"
Nettogewicht van de binnenunit128.97 pond
Nettogewicht van de buitenunit164.02 pond

10. Garantie en ondersteuning

ACiQ offers a comprehensive warranty for this heat pump system:

  • Garantie op onderdelen: 7 jaar
  • Garantie op compressor: 12 jaar

These warranty terms are valid when the system is installed by a certified technician and registered online with the manufacturer. For technical support, service inquiries, or warranty claims, please refer to the contact information provided in your product packaging or visit the official ACiQ webplaats.

Gerelateerde documenten - B0DHFF2DKL

Preview ACiQ 9K-24K Standard Heat Single-Zone Systemen: Installatie- en gebruikershandleiding
Installatie- en gebruikershandleiding voor ACiQ 9K-24K Standard Heat Single-Zone Systemen. Deze handleiding beschrijft de installatie, bediening, veiligheid en het onderhoud van ACiQ airconditioners, inclusief modelspecificaties en informatie over het koelmiddel R454B.
Preview ACiQ Central Inverter Systems Installation Manual
Comprehensive installation manual for ACiQ Central Inverter Air Conditioning and Heat Pump Systems, detailing safety precautions, refrigerant piping, outdoor unit installation, wiring, power specifications, air evacuation, and test run procedures.
Preview Installatie- en gebruikershandleiding voor de ACiQ wandgemonteerde luchtbehandelingsunit en de Extreme Heat Single-Zone condensor
Deze handleiding bevat gedetailleerde installatie-, bedienings- en veiligheidsrichtlijnen voor ACiQ-luchtbehandelingsapparaten voor wandmontage en extreem warme enkelzonecondensors, voor de modellen ACIQ-06W-HH-MD tot en met ACIQ-24ZPL-HP230C.
Preview Installatiehandleiding voor de buitenunit van ACiQ Central Inverter Systems
Uitgebreide installatiehandleiding voor buitenunits van ACiQ Central Inverter Systems, met informatie over veiligheidsmaatregelen, koelmiddelleidingen, bedrading, installatie van de unit en testprocedures voor modellen zoals de ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB en andere.
Preview ACiQ Next Gen Ducted Heat Pump System: Snelstartgids voor thermostaatbedrading
Deze handleiding biedt essentiële informatie voor het aansluiten en bedraden van thermostaten op het ACiQ Next Gen Ducted Heat Pump System. De handleiding beschrijft aanbevolen en alternatieve aansluitopties, inclusief DIP-switchinstellingen en klemmenblokconfiguraties voor verschillende thermostaattypen.
Preview ACiQ Essentials Mini-Split Air Handler & Condenser Installation and Owner's Manual
Comprehensive installation and owner's manual for ACiQ Essentials Mini-Split Air Handler and Condenser systems, covering safety precautions, parts identification, remote control operation, installation procedures, test runs, maintenance, and troubleshooting for various models. The manual also includes critical information regarding the servicing of systems using flammable refrigerant R454B, emphasizing safety protocols and regulatory compliance. It is designed for professional installers and end-users to ensure safe and efficient operation of ACiQ mini-split heat pump systems.