Invoering
This manual provides essential information for the safe and proper installation, operation, and maintenance of your Veepeak 30 Amp Flanged Outlet NEMA L14-30R Locking Receptacle. Please read all instructions carefully before installation and use. Retain this manual for future reference.
Veiligheidsinformatie
WAARSCHUWING: Electrical shock hazard. Improper installation or use can result in serious injury or death. Always follow local electrical codes and consult a qualified electrician if you are unsure about any part of the installation process.
- Always disconnect power at the circuit breaker or fuse box before installing or servicing this device.
- Ensure all wiring connections are secure and correct according to the wiring diagram and local codes.
- Overschrijd de opgegeven elektrische waarden van het apparaat niet.
- This product is designed for use with NEMA L14-30P compatible plugs only.
- Keep the weatherproof cap closed when the outlet is not in use to protect against moisture and dust.
Inhoud van het pakket
- 1 x Veepeak 30 Amp NEMA L14-30R Flanged Outlet
- Installatieschroeven
Specificaties
| Specificatie | Waarde |
|---|---|
| Amptijdperk | 30 Amps |
| Deeltage | 125/250 Volt wisselstroom |
| NEMA-configuratie | L14-30R |
| Poles / Wires | 3 Pole, 4 Wire Grounding |
| Maximale belasting | 7500 Watt |
| Aanbevolen draaddikte | 10AWG/4C |
| Materiaal | Polyvinylchloride (PVC) |
| Certificeringen | ETL Listed (Conforms to UL & CSA standards) |
| Vereiste gatgrootte | 2.5 inch |
Instellen en installeren
Benodigde gereedschappen: Screwdriver, wire strippers, drill (for mounting hole), appropriate drill bit.
- Montageplaats voorbereiden: Choose a suitable, dry location for installation. Drill a 2.5-inch diameter hole for the receptacle body. Ensure there is enough space behind the mounting surface for wiring connections.
- Bedradingsverbindingen:
Refer to the wiring diagram below and the color-coded terminals on the back of the receptacle. Strip approximately 1/2 inch of insulation from each wire. Insert the wires into the corresponding terminals and tighten the screws securely. Ensure no bare wire strands are exposed outside the terminals.

Afbeelding: Achterkant view of the L14-30R outlet, displaying the four color-coded terminals for wiring connections (Green for Ground, White for Neutral, Red and Black for Hot).

Image: NEMA L14-30R configuration diagram. 'X' and 'Y' are hot lines (125V each to neutral, 250V between them), 'W' is neutral, and 'G' is ground.
- Green (G): Aarddraad.
- Wit (B): Neutrale draad.
- Black (X): Hot wire (Line 1).
- Red (Y): Hot wire (Line 2).
- Monteer het stopcontact: Insert the receptacle body into the drilled hole. Secure the flanged outlet to the mounting surface using the provided screws. Ensure it is flush and stable.
- Herstel de stroom: Once installation is complete and all connections are verified, restore power at the circuit breaker.

Afbeelding: Voorzijde view of the Veepeak L14-30R flanged outlet with its weatherproof cap open, revealing the NEMA L14-30R locking receptacle.
Gebruiksaanwijzing
- De dop openen: Lift the weatherproof cap to access the receptacle.
- Connecting a Plug: Align the NEMA L14-30P plug with the receptacle. Insert the plug and twist clockwise to lock it into place. Ensure the plug is fully seated and locked.
- Disconnecting a Plug: Twist the plug counter-clockwise to unlock, then pull it straight out from the receptacle.
- Closing the Cap: When the outlet is not in use, ensure the weatherproof cap is securely closed over the receptacle to protect it from environmental elements like rain, snow, and dust.

Afbeelding: Voorzijde view of the Veepeak L14-30R flanged outlet with its weatherproof cap securely closed, providing protection.
Onderhoud
Regelmatig onderhoud zorgt voor optimale prestaties en veiligheid.
- Schoonmaak: Periodically clean the exterior of the outlet with a damp cloth. Do not use abrasive cleaners or solvents. Ensure the cap is closed during cleaning.
- Inspectie: Regularly inspect the outlet for any signs of damage, wear, or corrosion. Check the weatherproof cap for proper sealing.
- Verbindingscontrole: Annually, or if issues arise, disconnect power and check the wiring connections for tightness. Loose connections can cause overheating.
Probleemoplossing
- Geen stroom:
- Check the circuit breaker or fuse for the circuit. Reset if tripped.
- Controleer of de stroombron actief is.
- Ensure the plug is fully inserted and locked into the receptacle.
- Losse verbinding:
- If the plug feels loose or power is intermittent, disconnect power and inspect the wiring connections at the back of the receptacle for tightness.
- Inspect the plug on the appliance for damage.
- Damage to Outlet:
- If the outlet housing or terminals show signs of damage, cracking, or burning, discontinue use immediately and replace the unit.
Als de stappen voor probleemoplossing het probleem niet verhelpen, raadpleeg dan een gekwalificeerde elektricien.