1. Inleiding
This manual provides comprehensive instructions for the installation, operation, and maintenance of your Senville AURA Series Mini Split Air Conditioner Heat Pump. Please read this manual thoroughly before operating the unit to ensure proper use and to prevent damage.
The Senville AURA Series is designed to provide efficient cooling and heating for various spaces, including individual rooms, additions, garages, and commercial applications. It features DC Inverter Technology for high efficiency and quiet operation.

Figure 1.1: Complete Senville AURA Series Mini Split System Components.
2. Veiligheidsinformatie
Always adhere to the following safety precautions to reduce the risk of fire, electric shock, injury, or property damage.
- De installatie moet worden uitgevoerd door gekwalificeerd personeel in overeenstemming met alle toepasselijke lokale en nationale voorschriften.
- Zorg ervoor dat de voeding overeenkomt met de specificaties van het apparaat (208-230V).
- Steek geen vingers of voorwerpen in de luchtinlaat/-uitlaat.
- Probeer het apparaat niet zelf te repareren. Neem contact op met gekwalificeerd servicepersoneel.
- Schakel de stroomtoevoer uit voordat u gaat schoonmaken of onderhoud uitvoert.
3. Productcomponenten
The Senville AURA Series SENA-48HF/F system includes the following main components:
- (5) 9000 BTU Indoor Air Handlers
- (1) 48000 BTU Outdoor Condenser
- Wireless Remote Controls (one for each indoor unit)
- Pre-charged refrigerant lines (up to 125 ft)
- Installation accessories (drain hoses, electrical wiring, insulation tape)

Figure 3.1: Indoor Air Handler Unit.

Afbeelding 3.2: Draadloze afstandsbediening.

Afbeelding 3.3: Meegeleverde installatieaccessoires.
4. Installatie en instellingen
Installation of the Senville AURA Series mini split system requires specialized tools and knowledge. It is highly recommended that installation be performed by a certified HVAC technician.
4.1 Checklist voor installatie
- Controleer of alle componenten aanwezig en onbeschadigd zijn.
- Ensure adequate space for indoor and outdoor units, allowing for proper airflow and maintenance access.
- Confirm electrical supply meets 208-230V requirements and dedicated circuit is available.
4.2 Installatiestappen (Overview (voor Technicus)
- Mount indoor air handlers in desired locations, ensuring proper drainage.
- Position the outdoor condenser unit on a stable, level surface, away from obstructions.
- Connect refrigerant lines between indoor and outdoor units. The system is pre-charged for up to 125 feet of line.
- Connect electrical wiring according to the wiring diagram provided in the full installation manual.
- Voer een vacuümtrekking uit van de koelleidingen om lucht en vocht te verwijderen.
- Check for leaks using appropriate methods.
- Open service valves to release refrigerant.
- Test the system for proper operation in both cooling and heating modes.
5. Gebruiksaanwijzing
Your Senville AURA Series system is designed for user-friendly operation via the wireless remote control.
5.1 Functies afstandsbediening
Refer to Figure 3.2 for a visual guide to the remote control buttons.
- Aan/uit-knop: Schakelt het apparaat AAN/UIT.
- Modusknop: Schakelt tussen de bedrijfsmodi: Auto, Koelen, Ontvochtigen, Verwarmen, Ventilator.
- Temperatuurregeling: Gebruik de pijltoetsen OMHOOG/OMLAAG om de gewenste temperatuur in te stellen.
- Ventilatorsnelheid: Past de ventilatorsnelheid aan (Auto, Laag, Gemiddeld, Hoog).
- Schommel: Controls the louver swing for air distribution.
- ECO Gear: Activeert de energiebesparende modus.
- Tijdklok: Stelt AAN/UIT-timers in voor geplande werking.
5.2-bedrijfsmodi
- Koele modus: Provides cooling. Ideal for summer months.
- Warmtemodus: Provides heating. Effective down to -22°F (-30°C) with Arctic Heat Pump technology.
- Droge modus: Ontvochtigt de lucht.
- Ventilator modus: Laat de lucht circuleren zonder te verwarmen of te koelen.
- Automatische modus: Automatically selects cooling or heating based on ambient temperature.

Figure 5.1: Operating Temperature Range.
5.3 Slimme functies
- Whisper Technology: Ensures quiet operation, with noise levels as low as 23.5 dB.
- Smart Saving: Built-in intelligent eye detects human movement to automatically adjust operation and save energy.
- Slimme bediening: Compatible with voice control (e.g., Alexa) and app control (requires Alexa Kit installation).

Afbeelding 5.2: Geluidsarme werking.

Figure 5.3: Smart Saving Feature.

Figure 5.4: Smart Controls with Alexa Integration.
6. Onderhoud
Regular maintenance ensures optimal performance and longevity of your Senville AURA system.
6.1 Filterreiniging
- Reinig de luchtfilters elke twee weken, of vaker afhankelijk van het gebruik en de luchtkwaliteit.
- Open the front panel of the indoor unit, remove filters, and wash with lukewarm water.
- Laat de filters volledig drogen voordat u ze terugplaatst.
6.2 Onderhoud van de buitenunit
- Keep the area around the outdoor unit clear of debris, leaves, and snow.
- Reinig de buitenste warmtewisselaar periodiek met een zachte borstel of een stofzuiger.
- Zorg voor een goede afwatering vanaf de buitenunit.
6.3 Professionele service
It is recommended to have a certified HVAC technician perform annual inspections and maintenance, including checking refrigerant levels, electrical connections, and overall system performance.
7. Probleemoplossing
Voordat u contact opneemt met de klantenservice, raadpleeg dan de volgende veelvoorkomende problemen en oplossingen:
| Probleem | Mogelijke oorzaak | Oplossing |
|---|---|---|
| Het apparaat gaat niet aan. | Geen stroom, batterijen in de afstandsbediening leeg, stroomonderbreker uitgeschakeld. | Controleer de stroomvoorziening, vervang de batterijen van de afstandsbediening en reset de stroomonderbreker. |
| Onvoldoende koeling/verwarming. | Vervuilde luchtfilters, verstopte buitenunit, onjuiste modusinstelling, te weinig koelmiddel. | Maak de filters schoon, verwijder obstakels, selecteer de juiste modus en neem contact op met een technicus om het koelmiddel te laten controleren. |
| Ongebruikelijk geluid. | Losse onderdelen, geblokkeerde ventilator, normale bedrijfsgeluiden (bijv. koelmiddelstroom). | Controleer op losse onderdelen en verwijder obstakels. Als het geluid aanhoudt of aanhoudt, neem dan contact op met een technicus. |
| Waterlekkage uit binnenunit. | Verstopte afvoerslang, onjuiste installatie. | Check and clear drain hose. If issue persists, contact technician. |
8. Technische specificaties
| Functie | Specificatie |
|---|---|
| Modelnummer | SENA-48HF/F |
| Capaciteit | 48000 BTU (4 ton) |
| Binnenunits | (5) 9000 BTU Air Handlers |
| Buitenunit | (1) 48000 BTU Condenser |
| Deeltage | 208-230 Volts |
| Efficiëntie (SEER) | 22.0 |
| Geluidsniveau (binnen) | 23.5 dB (Whisper Technology) |
| Productafmetingen | 48"D x 48"W x 60"H (Overall System) |
| Speciale kenmerken | Heating and Cooling Function, DC Inverter Technology, Smart Saving, Smart Controls (Alexa compatible) |
| Certificeringen | ETL Intertek Approved, AHRI Certified, ENERGYSTAR |
9. Garantie-informatie
The Senville AURA Series is backed by a comprehensive warranty:
- Garantie op onderdelen: 5 jaar
- Garantie op compressor: 10 jaar
For detailed warranty terms and conditions, please refer to the warranty card included with your product or visit the official Senville webplaats.
10. Klantenservice
For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact Senville customer support.
- Webwebsite: Visit the Senville Store on Amazon
- Algemene vragen: Refer to the contact information provided in your product packaging or on the official Senville webplaats.

Figure 10.1: Senville Customer Support.