1. Inleiding
The C-LOGIC 5100 is a manual ranging digital multimeter designed for precise electrical measurements. This versatile instrument is capable of measuring AC/DC voltage, AC/DC current, resistance, capacitance, frequency, temperature, and transistor hFE. It features a durable rubber housing for enhanced grip and comfort, along with a hinged bracket for convenient table-top operation. This manual provides essential information for the safe and effective use of your C-LOGIC 5100 Digital Multimeter.
2. Veiligheidsinformatie
Always observe the following safety precautions when operating the C-LOGIC 5100 Digital Multimeter to prevent personal injury or damage to the instrument:
- Ensure the multimeter is set to the correct function and range before connecting the test leads to any circuit.
- Do not exceed the maximum input values specified for each function. The C-LOGIC 5100 is rated for CAT III 600V.
- Koppel de testkabels los van het circuit voordat u functies of bereiken wijzigt.
- Inspect test leads for damaged insulation or exposed metal before each use. Replace damaged leads immediately.
- Gebruik de multimeter niet als deze beschadigd lijkt of als de behuizing open is.
- Wees uiterst voorzichtig bij het werken met voltagGebruik geen apparaten met een spanning hoger dan 60V DC of 30V AC RMS, aangezien deze een risico op een elektrische schok vormen.
- Remove test leads from the multimeter before opening the battery compartment or fuse cover.
3. Producteigenschappen
The C-LOGIC 5100 Digital Multimeter incorporates several features designed for user convenience and functionality:
- Rubberen behuizing: Provides improved grip and protection against accidental drops.
- Hinged Bracket: Allows the multimeter to stand upright for hands-free operation on a workbench.
- Meetmogelijkheden: AC/DC-voltage, AC/DC Current, Resistance, Capacitance, Frequency, Temperature, and Transistor hFE.
- Weergaveaantallen: 2000-count digital display for clear readings.
- Automatische uitschakeling (APO): Automatically turns off the device after a period of inactivity to conserve battery life.
- Gegevensopslag: Hiermee wordt de weergegeven waarde bevroren voor gemakkelijke notatie.
- Low Battery Display (LBD): Geeft aan wanneer de batterij aan vervanging toe is.
- Diode Test and Continuity Buzzer: For testing diodes and checking circuit continuity.
4. Componenten en bedieningselementen

Figuur 1: Voorkant view of the C-LOGIC 5100 Digital Multimeter, showing the display, function selector, and input jacks.
Familiarize yourself with the main components of your multimeter:
- LCD-scherm: Toont meetwaarden, eenheden en functie-indicatoren.
- Function/Range Selector Dial: Hiermee kunt u de gewenste meetfunctie en het meetbereik selecteren.
- Pauzeknop: Druk om de huidige waarde op het display te bevriezen. Druk nogmaals om los te laten.
- Aan / uit knop: Hiermee wordt de multimeter in- of uitgeschakeld.
- Ingangsaansluitingen:
- VΩHzTemp: Positieve input voor voltage, resistance, frequency, temperature, capacitance, diode, and continuity measurements.
- COM: Gemeenschappelijke (negatieve) ingang voor alle metingen.
- mA: Positive input for current measurements up to 200mA.
- 10A: Positive input for current measurements up to 10A (MAX 30 sec. every 15 min.). This input is fused.
- hFE-socket: For testing transistor hFE (DC current gain).
5. Instellen
5.1 Batterij installatie
The C-LOGIC 5100 requires one 9V 6F22 battery (not included). To install or replace the battery:
- Zorg ervoor dat de multimeter UIT staat en koppel alle meetsnoeren los van de ingangen.
- Zoek het klepje van het batterijcompartiment aan de achterkant van het apparaat.
- Draai de bevestigingsschroef/schroeven los en verwijder voorzichtig de afdekking.
- Sluit de 9V-batterij aan op de batterijclip en let daarbij op de juiste polariteit.
- Plaats de batterij in het compartiment en sluit het deksel weer af, waarna u het vastdraait met de schroef/schroeven.
5.2 Aansluiting van de testkabel
Een correcte aansluiting van de meetsnoeren is cruciaal voor nauwkeurige en veilige metingen:
- Voor de meeste metingen (voltage, resistance, capacitance, frequency, temperature, diode, continuity), insert the rood testleiding in de VΩHzTemp jack en de zwart testleiding in de COM krik.
- For current measurements up to 200mA, insert the rood testleiding in de mA jack en de zwart testleiding in de COM krik.
- Voor stroommetingen tot 10A plaatst u de rood testleiding in de 10A jack en de zwart testleiding in de COM krik.
6. Gebruiksaanwijzing

Figuur 2: The C-LOGIC 5100 Digital Multimeter actively measuring voltage in een elektrisch paneel.
Follow these general steps for making measurements:
- Turn the multimeter ON using the ON/OFF switch.
- Select the desired function and appropriate range using the rotary dial. If unsure of the range, start with the highest range and work downwards.
- Sluit de meetsnoeren aan op het circuit of het te testen onderdeel.
- Lees de meetwaarde af op het lcd-scherm.
- After measurement, disconnect the test leads and turn the multimeter OFF.
6.1 Specifieke meetfuncties
- DC voltage (V=): Select the V= range. Connect the red lead to the positive side and the black lead to the negative side of the DC voltage-bron parallel.
- AC voltage (V~): Select the V~ range. Connect the test leads across the AC voltage source in parallel. Polarity is not critical for AC voltage.
- Gelijkstroom (A=): Select the A= range (mA or 10A jack). Disconnect power to the circuit. Open the circuit where current is to be measured and connect the multimeter in series. Reapply power.
- Wisselstroom (A~): Select the A~ range (mA or 10A jack). Follow the same series connection procedure as for DC current.
- Weerstand (Ω): Select the Ω range. Ensure the circuit is de-energized. Connect the test leads across the component to measure its resistance.
- Continuïteitstest (♫): Select the continuity function. If resistance is below approximately 50Ω, the buzzer will sound, indicating continuity.
- Diodetest (→|→): Select the diode function. Connect the red lead to the anode and the black lead to the cathode of the diode. The display will show the forward voltage-drop. Draai de draden om; op het display moet 'OL' (open loop) verschijnen als de diode goed is.
- Capaciteit (F): Select the F range. Ensure the capacitor is discharged before connecting the test leads.
- Frequentie (Hz): Select the Hz range. Connect the test leads across the signal source.
- Temperatuur (Temp): Select the Temp range. Connect a K-type thermocouple (if included or purchased separately) to the VΩHzTemp and COM jacks.
- Transistor hFE: Insert the transistor's emitter, base, and collector leads into the corresponding holes in the hFE socket, ensuring correct NPN/PNP type selection.
7. Onderhoud
7.1 Batterij vervangen
When the low battery indicator appears on the display, replace the 9V battery as described in Section 5.1. Using a multimeter with a low battery can lead to inaccurate readings.
7.2 Reinigen
Om de multimeter schoon te maken, veegt u de behuizing schoon met een doekje.amp cloth and a mild detergent. Do not use abrasive cleaners, solvents, or alcohol, as these may damage the casing or display. Ensure the multimeter is completely dry before use.
7.3 Zekering vervangen
If the 10A current measurement function stops working, the fuse may need replacement. This procedure should only be performed by qualified personnel. Refer to the specifications for the correct fuse type and rating. Always disconnect test leads and power off the unit before opening the case.
8. Probleemoplossing
If your C-LOGIC 5100 Multimeter is not functioning as expected, refer to the following common issues and solutions:
- Geen scherm: Check if the multimeter is turned ON. Verify the 9V battery is correctly installed and has sufficient charge. Replace the battery if necessary.
- Onjuiste metingen: Ensure the correct function and range are selected for the measurement. Check that the test leads are securely connected to the correct input jacks and to the circuit. Verify the battery is not low.
- 'OL' (Overbelasting) indicatie: This indicates that the input value exceeds the selected range. Switch to a higher range or ensure the input is within the multimeter's maximum specifications.
- Geen continuïteitszoemer: Check if the continuity function is selected. Ensure the circuit is de-energized.
- Huidige meting werkt niet: Check the fuse for the current input (especially the 10A input). Replace if blown. Ensure test leads are connected to the correct current jacks (mA or 10A) and the multimeter is in series with the circuit.
9. Specificaties

Figuur 3: Detailed specifications and features of the C-LOGIC 5100 Digital Multimeter.
| Meting | Bereik/Waarde |
|---|---|
| DC voltage | Tot 600V |
| AC voltage | Tot 600V |
| DC-stroom | Tot 10A |
| AC stroom | Tot 10A |
| Weerstand | Tot 200MΩ |
| Capaciteit | Tot 100 µF |
| Frequentie | Tot 20 kHz |
| Temperatuur | -20°C tot 1000°C / 1°F tot 1832°F |
| Tellingen weergeven | 2000 |
| Stroomvoorziening | 1x 9V 6F22 Battery |
| Productafmetingen (LxBxH) | 18.8 x 9.3 x 5 cm (7.4 x 3.7 x 1.96 inch) |
| Productgewicht | 380 gram (0.84 pond) |
| Veiligheidsclassificatie | KAT III 600V |
| Certificeringen | CE, ETL, RoHS |
10. Main Applications

Figuur 4: Visual representation of common domestic and electronics applications for the C-LOGIC 5100 Multimeter.
The C-LOGIC 5100 Digital Multimeter is suitable for a wide range of applications, including:
- Domestic Electrical Testing: Checking household wiring, outlets, batteries, and appliance continuity.
- Autodiagnostiek: Testing vehicle electrical systems, battery voltage, and component resistance.
- Electronics Troubleshooting: Meetvolumetage, current, resistance, and capacitance in electronic circuits, testing diodes and transistors.
- HVAC System Checks: Verifying voltage and current in heating, ventilation, and air conditioning systems.
- Hobbyist and DIY Projects: Essential tool for various electrical and electronic projects.
11. Garantie en ondersteuning