GVS SPR451

GVS Elipse P100 Dust Half Mask Respirator

Model: SPR451

1. Inleiding

The GVS Elipse P100 Dust Half Mask Respirator is designed to provide personal respiratory protection against dust and fumes. Its compact and lightweight design ensures comfort and a full range of vision, making it suitable for various industrial and safety applications. This manual provides essential information for the proper use, maintenance, and care of your respirator.

GVS Elipse P100 Dust Half Mask Respirator, front view

Figuur 1: Voorzijde view of the GVS Elipse P100 Respirator.

Video 1: Overview of Elipse respirators by GVS, highlighting key features and benefits.

2. Opstellen en monteren

Proper fitting is crucial for effective respiratory protection. Follow these steps to correctly set up and wear your GVS Elipse P100 Respirator:

  1. Controleer het ademhalingsapparaat: Before each use, check the mask body, straps, and filters for any signs of damage, cracks, or wear. Ensure the filters are securely attached.
  2. Hoofdbanden aanpassen: Hold the respirator with one hand and pull the head straps over your head with the other. Position the mask over your nose and mouth. The top strap should rest on the crown of your head, and the neck strap should rest around your neck below your ears.
  3. Maak de riemen strakker: Pull the ends of the straps to tighten the mask until it feels secure but comfortable. Do not overtighten. The mask should fit snugly against your face without gaps.
  4. Perform a Seal Check:
    • Controle van de positieve druk: Place the palm of your hand over the exhalation valve cover (front center of the mask) and gently exhale. The mask should slightly bulge outwards, and you should feel no air leaking from the edges.
    • Controle van de onderdruk: Place the palms of your hands over the filter covers on both sides of the mask and gently inhale. The mask should pull inward towards your face, and you should feel no air leaking from the edges.
    If you detect any leaks during the seal check, readjust the straps and repeat the check. If leaks persist, the mask may be damaged or incorrectly sized.
GVS Elipse P100 Dust Half Mask Respirator, back view with straps

Afbeelding 2: Terug view of the respirator showing adjustable straps.

Video 2: An unboxing and fitting demonstration of the GVS Elipse P100 Respirator.

3. Gebruiksaanwijzing

Once properly fitted, the GVS Elipse P100 Respirator provides effective protection in environments containing dust and fumes. It is recommended for use in situations involving micro-organisms, marble, gypsum, titanium oxide, rock wool, wood, detergents, and various dusts that can cause lung disease, including asbestos, bauxite, coal, silica, and iron.

The mask's compact design allows for a full range of vision and does not interfere with other personal protective equipment (PPE) such as eye or ear protection. Its low breathing resistance minimizes user fatigue during extended periods of use.

Worker wearing GVS Elipse P100 Respirator while drilling into concrete

Figure 3: Worker using the respirator during drilling, demonstrating compatibility with safety glasses.

Video 3: Demonstrates the comfort and lightweight nature of the mask during use.

Video 4: Emphasizes the importance of wearing a respirator for protection in dusty environments.

4. Onderhoud

Regular maintenance ensures the longevity and effectiveness of your respirator. Filters should be replaced when breathing resistance becomes noticeably high or when odors are detected.

4.1 Filtervervanging

  1. Remove Used Filters: Gently twist and pull the filter covers to detach them from the mask body. Remove the old filter cartridges.
  2. Nieuwe filters invoegen: Align the new filter cartridges with the openings on the mask body and push them firmly into place until they click. Ensure a secure fit.
  3. Reattach Covers: Place the filter covers back over the new filters and twist to lock them into position.

Video 5: Detailed instructions on how to remove and replace the Elipse P100 filters.

4.2 Reiniging en opslag

5. Probleemoplossing

If you encounter issues with your GVS Elipse P100 Respirator, consider the following:

6. Specificaties

FunctieDetail
ModelnummerSPR451
GoedkeuringNIOSH Approval number: P100 TC-84A-6949 (Meets 42CFR84 requirements)
MateriaalThermoplastic Elastomers (TPE)
KleurBlauw
MaatSmall/Medium (Elipse comes in 2 sizes)
Productafmetingen5 x 4 x 4 inch
Gewicht6.4 ons
Land van herkomstVerenigd Koninkrijk

7. Garantie en ondersteuning

For detailed warranty information and support, please refer to the official GVS user manual available in PDF format. Please note that no returns are allowed on this product.

Officiële gebruikershandleiding (PDF): Download hier

Gerelateerde documenten - SPR451

Preview GVS Elipse Low Profile Gebruiksaanwijzing voor het gecombineerde gas- en deeltjesfiltermasker
Uitgebreide gebruiksaanwijzing voor de GVS Elipse low profile combined gas and particulate safety respirator. Covers applications, filter types, fitting, cleaning, maintenance, storage, warnings, limitations, and service life. Essential guide for occupational safety.
Preview GVS Smart APP V1.4 Gebruikershandleiding
Gebruikershandleiding voor de GVS Smart APP V1.4, met gedetailleerde informatie over het bedienen en beheren van KNX- en smart home-apparaten van derden, het instellen van scènes, het integreren van spraakassistenten en het autoriseren van services van derden, zoals SONOS.
Preview GVS Gem Series Z10 Smart Home Server Gebruikershandleiding (A-IS03)
Gebruikershandleiding voor de GVS Gem Series Z10 Smart Home Server (model A-IS03), met gedetailleerde informatie over de functies, installatie en bediening voor intercom- en smart home-besturingssystemen.
Preview GVS K-BUS KNX Gateway voor RS485/RS232 Gebruikershandleiding V1.8
This user manual provides comprehensive technical details, installation, and programming guidance for the GVS K-BUS KNX Gateway for RS485/RS232 (V1.8). Learn how to integrate Modbus, RS485, and RS232 devices with KNX home and building control systems.
Preview GVS K-BUS KNX Gateway for Tuya ZigBee V2.1 User Manual
This user manual provides detailed technical information, installation, and programming guidance for the GVS K-BUS KNX Gateway for Tuya ZigBee V2.1, enabling seamless integration between KNX and Tuya ZigBee smart home systems.
Preview K-BUS KNX Gateway for IR V1.4 User Manual
Comprehensive user manual for the GVS K-BUS KNX Gateway for IR V1.4, detailing specifications, installation, configuration, and communication objects for both Flush mounted (BTIRF-02/00.2) and Ceiling (BTIRC-01/00.2) models. This guide covers parameter settings within ETS and application examples for home and building automation.