Invoering
This manual provides essential information for the installation, operation, and maintenance of the ADTRAN NetVanta 3140 Router. The NetVanta 3140 is a fixed-port, high-performance Ethernet router designed to support converged access and high-quality Voice services. It features three routed, autosensing Gigabit Ethernet interfaces, making it suitable for enterprise-class Internet access and secure corporate connectivity.
Veiligheidsinformatie
Always observe basic safety precautions to reduce the risk of fire, electric shock, and injury to persons, including the following:
- Lees alle instructies zorgvuldig door voordat u het apparaat gebruikt.
- Stel het apparaat niet bloot aan regen of vocht.
- Open het apparaat niet casing. Laat al het onderhoud uitvoeren door gekwalificeerd servicepersoneel.
- Zorg voor voldoende ventilatie rond het apparaat.
- Gebruik alleen de voedingsadapter die bij het apparaat is geleverd.
Inhoud van het pakket
Controleer of uw pakket de volgende items bevat:
- ADTRAN NetVanta 3140 Router (Model: 1700341F1)
- Stroomadapter
- Documentatie (Snelstartgids, Garantie-informatie)
Note: Rack-mounting hardware may be sold separately.
Fysiek voorbijview
The ADTRAN NetVanta 3140 features various ports and indicators on its front and rear panels. Familiarize yourself with these components before installation.

Figure 1: Front Panel of NetVanta 3140 Router
This image displays the front panel of the ADTRAN NetVanta 3140 router. From left to right, it shows status LEDs (STAT, USB), three Gigabit Ethernet ports labeled GIG 0/1, GIG 0/2, and GIG 0/3, two USB ports, and a CONSOLE port (DB9 serial connector). The ADTRAN logo is visible on the left, and "NetVanta 3140" is printed on the right.
Onderdelen van het frontpaneel:
- STAT LED: Geeft de systeemstatus aan.
- USB-LED: Indicates USB activity.
- GIG 0/1, GIG 0/2, GIG 0/3 Ports: Three autosensing Gigabit Ethernet interfaces for network connections.
- USB-poorten: Voor het aansluiten van compatibele USB-apparaten.
- CONSOLE-poort: A DB9 serial port for local management and configuration via a terminal emulator.
Instellen
1. Plaatsing
Place the NetVanta 3140 on a flat, stable surface or install it in a standard 19-inch equipment rack (rack-mounting hardware not included). Ensure adequate ventilation and avoid placing the device near heat sources or in direct sunlight.
2. Stroomaansluiting
- Connect the provided power adapter to the power input on the rear panel of the router.
- Steek het andere uiteinde van de voedingsadapter in een geschikt stopcontact.
- The device will power on automatically. Observe the STAT LED for boot-up sequence.
3. Netwerkverbindingen
- Connect your Internet service provider's (ISP) modem or network uplink to one of the Gigabit Ethernet ports (e.g., GIG 0/1).
- Connect your local area network (LAN) devices (e.g., computers, switches) to the remaining Gigabit Ethernet ports.
- Zorg ervoor dat alle Ethernetkabels goed zijn aangesloten.
4. Initial Configuration (Console Access)
For initial configuration or advanced management, connect a computer to the CONSOLE port using a serial cable (DB9). Use a terminal emulation program (e.g., PuTTY, Tera Term) with the following settings:
- Baud Rate: 9600
- Gegevensbits: 8
- parity: Geen
- Stopbits: 1
- Stroomregeling: Geen
Refer to the ADTRAN OS documentation for detailed command-line interface (CLI) configuration instructions.
Gebruiksaanwijzing
Systeem opstarten
Upon power-on, the router will perform a self-test and load the ADTRAN OS. The STAT LED will blink during this process and become solid green once the system is operational.
LED-indicatoren
| LED | Staat | Beschrijving |
|---|---|---|
| STAAT | Effen Groen | System operational. |
| Knipperend Groen | System booting or performing self-test. | |
| Uit | No power or system failure. | |
| USB | Effen Groen | USB device connected and active. |
| Knipperend Groen | USB data transfer in progress. | |
| Uit | No USB device connected or inactive. | |
| GIG Ports (Link/Activity) | Effen Groen | Koppeling tot stand gebracht. |
| Knipperend Groen | Gegevensactiviteit. | |
| Uit | No link or no activity. |
Basisnetwerkwerking
Once configured, the NetVanta 3140 will route traffic between its Gigabit Ethernet interfaces according to its configuration. It supports features such as Quality of Service (QoS) for prioritizing traffic and Voice over IP (VoIP) readiness for voice services.
Onderhoud
Firmware-updates
Controleer periodiek de ADTRAN-ondersteuning. website for firmware updates. Keeping the router's firmware up-to-date ensures optimal performance, security, and access to new features. Follow the instructions provided with the firmware update package carefully.
Schoonmaak
To clean the device, power it off and disconnect the power adapter. Use a soft, dry cloth to wipe the exterior. Do not use liquid or aerosol cleaners, as they may damage the device.
Milieuoverwegingen
Zorg ervoor dat de bedrijfsomgeving binnen de gespecificeerde temperatuur- en vochtigheidsbereiken blijft om schade te voorkomen en een betrouwbare werking te garanderen.
Probleemoplossing
Geen stroom
- Verify the power adapter is securely connected to both the router and a working electrical outlet.
- Controleer of het stopcontact werkt door er een ander apparaat op aan te sluiten.
- Ensure the power adapter is the correct one supplied with the device.
Geen netwerkverbinding
- Check the Ethernet cable connections to the GIG ports. Ensure they are firmly seated.
- Observe the GIG port LEDs. If they are off, there might be no link. Try a different cable or port.
- Verify the configuration of the router using the console port.
- Restart the router and connected network devices.
Console Access Issues
- Ensure the serial cable is correctly connected to the CONSOLE port and your computer.
- Verify the terminal emulation software settings (baud rate, data bits, parity, stop bits, flow control) match the recommended settings.
- Check if the correct COM port is selected in your terminal software.
Specificaties
| Functie | Detail |
|---|---|
| Modelnummer | 1700341F1 |
| Merk | ADTRAN |
| Connectiviteitstechnologie | Ethernet |
| Aantal Ethernet-poorten | 3 (Gigabit Ethernet) |
| Aantal USB 2.0-poorten | 1 |
| Console-poort | DB9-serie |
| Besturingssysteem | ADTRAN OS |
| Hardwareplatform | PC |
| Artikelgewicht | 3.05 pond (1.38 kg) |
| Productafmetingen (LxBxH) | 12.5 x 11.25 x 5 cm (31.75 x 28.58 x 12.7 inch) |
| Speciale kenmerken | QoS, WPS |
| Antennetype | Intern |
| Aanbevolen gebruik | Bedrijf |
Garantie en ondersteuning
Garantie-informatie
ADTRAN products are covered by a limited warranty. For specific warranty terms and conditions, please refer to the warranty documentation included with your product or visit the official ADTRAN webwebsite. Bewaar uw aankoopbewijs voor garantieclaims.
Technische ondersteuning
For technical assistance, product documentation, or firmware downloads, please visit the official ADTRAN support portal. You can typically find support resources, FAQs, and contact information for technical support there.
ADTRAN Official Webwebsite: www.adtran.com