1. Overview

The Fluke 77-4 Digital Multimeter is a robust and reliable tool designed for industrial electrical troubleshooting. It offers essential measurement capabilities with enhanced safety features, including a CAT III 1000V rating. This manual provides instructions for safe and effective use, setup, operation, and maintenance of your Fluke 77-4 multimeter.

2. Veiligheidsinformatie

Always adhere to safety precautions when using any electrical test equipment. Failure to do so may result in injury or damage to the multimeter or equipment under test.

3. Producteigenschappen

The Fluke 77-4 Multimeter includes the following key features:

4. Componenten en bedieningselementen

Familiarize yourself with the various parts of your Fluke 77-4 Multimeter:

Fluke 77-4 Digital Multimeter showing a reading of 1000V AC

Figuur 1: Voorzijde view of the Fluke 77-4 Digital Multimeter.

Deze afbeelding toont de voorkant view of the Fluke 77-4 Digital Multimeter. The large green backlit LCD shows '1000 V AC' with 'Auto Range' indicated below. Below the display are buttons for HOLD, MINMAX, and RANGE. The central rotary dial is set to the AC Voltage (V~) position. Input jacks for 400mA, 10A, VΩHz, and COM are visible at the bottom.

  1. Weergave: Large LCD for showing measurement values, units, and function indicators.
  2. Achtergrondverlichtingsknop: Hiermee kunt u de achtergrondverlichting van het scherm in- of uitschakelen.
  3. Pauzeknop: Bevriest de huidige weergave.
  4. MINMAX Button: Records the minimum, maximum, and average readings over time.
  5. RANGE-knop: Schakelt tussen de automatische en handmatige afstandsmetingsmodus.
  6. Rotary Function Dial: Selects the desired measurement function (e.g., V AC, V DC, Ohms, AmpS).
  7. Ingangsaansluitingen:
    • VΩHz: Positieve input voor voltage, weerstand- en frequentiemetingen.
    • mA: Invoer voor milliamphuidige metingen (gesmolten).
    • 10A: Input for high current measurements up to 10 Amperes (fused).
    • COM: Gemeenschappelijke (negatieve) ingang voor alle metingen.

5. Instellen

5.1. Batterij installatie

The Fluke 77-4 is powered by a 9V battery. To install or replace the battery:

  1. Zorg ervoor dat de multimeter is uitgeschakeld.
  2. Locate the battery compartment cover on the rear of the multimeter.
  3. Draai de schroef/schroeven los waarmee de kap vastzit.
  4. Remove the cover and insert a new 9V battery, observing correct polarity.
  5. Replace the cover and tighten the screw(s).

5.2. Testkabels aansluiten

Always connect the black test lead to the COM jack. Connect the red test lead to the appropriate input jack for your measurement:

6. Gebruiksaanwijzing

Before taking any measurement, ensure the test leads are correctly connected and the function dial is set to the appropriate position.

6.1. AC/DC-spanning metentage

  1. Turn the rotary dial to V~ (AC Voltage) or V (DC Voltagen).
  2. Connect the black test lead to the COM jack and the red test lead to the VΩHz jack.
  3. Touch the test probes to the circuit points where voltage moet worden gemeten.
  4. Lees het deeltage-waarde op het display.

6.2. Measuring Resistance (Ohms)

  1. Zorg ervoor dat het circuit spanningsloos is voordat u de weerstand meet.
  2. Turn the rotary dial to Ω.
  3. Connect the black test lead to the COM jack and the red test lead to the VΩHz jack.
  4. Touch the test probes across the component or circuit segment.
  5. Lees de weerstandswaarde af op het display.

6.3. Measuring Current (Amperes)

Voorzichtigheid: Current measurements require breaking the circuit and inserting the multimeter in series. Incorrect connection can blow the fuse or damage the meter.

  1. Maak het circuit spanningsloos.
  2. Determine the expected current range. For currents up to 400mA, turn the dial to mA and connect the red lead to the mA jack. For currents up to 10A, turn the dial to A and connect the red lead to the 10A jack.
  3. Sluit het zwarte testsnoer aan op de COM-aansluiting.
  4. Break the circuit and connect the test probes in series with the load.
  5. Re-energize the circuit and read the current value.
  6. De-energize the circuit before disconnecting the multimeter.

6.4. Using HOLD, MINMAX, and RANGE Functions

7. Onderhoud

7.1. Schoonmaken

Veeg de behuizing af met advertentieamp cloth and mild detergent. Do not use abrasives or solvents. Ensure the multimeter is dry before use.

7.2. Batterij vervangen

Refer to Section 5.1 for battery installation instructions. Replace the battery when the low battery indicator appears on the display.

7.3. Zekering vervangen

If the multimeter fails to measure current, the fuse may be blown. Refer to the multimeter's internal diagram or contact Fluke support for correct fuse specifications and replacement procedures. Always use fuses with the specified voltage en huidige beoordelingen.

8. Probleemoplossing

ProbleemMogelijke oorzaakOplossing
Geen weergave of zwak displayLage of lege batterijVervang de 9V-batterij.
Cannot measure currentBlown fuse in current inputReplace the appropriate fuse (mA or 10A).
Incorrect or unstable readingsPoor test lead connection, incorrect function selection, or external interference.Check lead connections, verify function dial setting, move away from strong electromagnetic fields.
"OL" (Overload) wordt weergegevenDe meting overschrijdt het geselecteerde bereik of de maximale capaciteit van de meter.Switch to a higher range (if in manual mode) or ensure the measurement is within the meter's specifications.

9. Specificaties

ParameterWaarde
MerkVlek
Modelnummer77-4
MeettypeDigitale multimeter
VeiligheidsclassificatieKAT III 1000V
DC voltage Bereik6 V - 1000 V
AC voltage Bereik600mV - 1000V
EnergiebronWerkt op batterijen (9V)
KleurGeel/Zwart
Artikelgewicht2 pond (ongeveer 0.91 kg)
min. Bediening Voltage6 Volt (DC)
Bovenste temperatuurclassificatie122 graden Fahrenheit (50 graden Celsius)
UPC095969365239
FabrikantVlek
Datum eerste beschikbaarheid10 mei 2019

10. Garantie-informatie

Specific warranty terms for the Fluke 77-4 Digital Multimeter are typically provided with the product at the time of purchase or can be found on the official Fluke website. Please refer to your product documentation or the manufacturer's website for detailed warranty coverage and registration information.

11. Klantenservice

For technical assistance, service, or repair, please contact Fluke customer support. You can find contact information and additional resources on the official Fluke website. When contacting support, please have your product model number (77-4) and serial number (if applicable) ready.

Vlek Webwebsite: www.fluke.com

Gerelateerde documenten - 77-4

Preview Fluke 107 Handheld CAT III Digital Multimeter - Technical Specifications
Detailed technical specifications, features, and general information for the Fluke 107 handheld CAT III digital multimeter. Includes electrical measurements, safety ratings, and ordering details.
Preview Fluke 179 digitale multimeter: onderhouds- en servicehandleiding
Ontdek de Fluke 179 True-RMS digitale multimeter, ontworpen voor efficiënt elektrisch en HVAC-onderhoud. Lees meer over de kenmerken, specificaties en aanbevolen accessoires voor betrouwbare service in het veld.
Preview Fluke 107 CAT III Digitale Multimeter Specificaties en Kenmerken
Gedetailleerde specificaties, kenmerken en technische gegevens voor de Fluke 107 CAT III digitale multimeter in handpalmformaat. Inclusief elektrische en algemene specificaties, afmetingen, garantie en informatie over EURO-INDEX diensten.
Preview Fluke Model 77 Serie IV Digitale Multimeter Gebruikershandleiding
Uitgebreide gebruikershandleiding voor de Fluke Model 77 Serie IV digitale multimeter, met informatie over functies, metingen, veiligheid, specificaties en probleemoplossing. Inclusief gedetailleerde instructies en technische gegevens.
Preview Fluke 116 True-rms Multimeter: Quick Reference Guide
Quick reference guide for the Fluke 116 True-rms Multimeter, detailing its functions, measurement capabilities, and usage for electrical testing.
Preview Fluke 110 True-RMS Multimeter: Technical Specifications and Features
Detailed specifications and features of the Fluke 110 compact True-RMS multimeter, designed for precise electrical installation and troubleshooting. Includes accuracy, safety ratings, and included accessories.