1. Product voorbijview
The Sicce Ultrazero Flat Sucking Pump is designed for efficient removal of water from various areas, including flooded cellars, garages, and other spaces where minimal residual water is desired. This submersible pump is capable of reducing water levels down to 2-3 mm.
Belangrijkste kenmerken:
- Capable of pumping water down to 2 mm residual level.
- Fully submersible design.
- Handles dirt particles up to 3 mm in size.
- Equipped with a 10-meter power cable.
- Features a practical carry handle for easy transport.

Figuur 1: Overview of the Sicce Ultrazero Flat Sucking Pump.
2. Veiligheidsinformatie
Read all safety warnings and instructions before operating the pump. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Koppel de pomp altijd los van de stroomvoorziening voordat u deze aanraakt, schoonmaakt of onderhoudt.
- Zorg ervoor dat de voeding voltage matches the pump's specifications (230 V/50 Hz).
- Do not operate the pump with a damaged power cord or plug. If damaged, it must be replaced by the manufacturer, service agent, or similarly qualified persons to avoid a hazard.
- Do not use the pump to handle flammable or explosive liquids.
- Houd kinderen en onbevoegde personen uit de buurt van het werkgebied.
- Ensure the pump is fully submerged during operation to prevent overheating.
- Avoid running the pump dry for extended periods.
- This pump is designed for water only. Do not use it for other liquids without consulting the manufacturer.
3. Installatie en installatie
Follow these steps to properly set up your Ultrazero pump:
- Pak de pomp uit: Haal de pomp en alle accessoires voorzichtig uit de verpakking. Controleer op eventuele beschadigingen.
- Connect the Discharge Hose:
The pump features a 26.44 mm (3/4") AG pressure connection. Attach a suitable discharge hose (e.g., 20 mm (3/4") hose connection) to this outlet. Ensure the connection is secure to prevent leaks.

Figure 2: Close-up of the pump's discharge outlet and integrated carry handle.
- Plaats de pomp: Place the pump directly on the surface from which water needs to be removed. Ensure the pump is stable and upright. The flat base allows for efficient water removal down to minimal levels.
- Route the Discharge Hose: Direct the discharge hose to a suitable drainage area, ensuring the water will not flow back into the area being drained.
- Stroomaansluiting: Plug the 10-meter power cable into a grounded 230 V/50 Hz electrical outlet. Ensure the outlet is protected by a Ground Fault Circuit Interrupter (GFCI) for added safety, especially in wet environments.

Figure 3: The flat base of the pump designed for low residual water levels.
4. Gebruiksaanwijzing
The Ultrazero pump is designed for simple operation:
- Dompel de pomp onder: Ensure the pump is fully submerged in the water you wish to remove. The pump requires water to cool its motor and operate correctly.
- Begin met pompen: Once submerged and connected to power, the pump will begin operating automatically. It does not feature a float switch, so manual monitoring is required for optimal use.
- Waterniveau bewaken: The pump will continue to operate until the water level reaches its minimum suction capability of 2-3 mm.
- Stop met pompen: To stop the pump, disconnect it from the power supply. It is recommended to disconnect the pump once the desired water level is reached or if the pump starts to run dry.

Figure 4: The Ultrazero pump effectively draining water from a small pool.

Figure 5: The pump in action on a flooded floor, demonstrating its low-level suction capability.

Figure 6: Illustration of the pump's ability to reduce water levels to approximately 2 mm.
5. Onderhoud
Regelmatig onderhoud zorgt ervoor dat uw pomp lang meegaat en optimaal presteert.
- Schoonmaak: After each use, especially when pumping dirty water, rinse the pump thoroughly with clean water. This helps prevent sediment buildup.
- Inspecteer op vuil: Periodically check the pump's intake area for any debris (e.g., leaves, small stones) that might obstruct water flow. Remove any blockages carefully after disconnecting power.
- Kabelinspectie: Regularly inspect the power cable for cuts, abrasions, or other damage. Do not use the pump if the cable is damaged.
- Opslag: When not in use, store the pump in a clean, dry place, protected from frost.

Figure 7: The pump can also be used for transferring water for tasks like garden watering from a rain barrel.
6. Probleemoplossing
If you encounter issues with your Ultrazero pump, refer to the following common problems and solutions:
| Probleem | Mogelijke oorzaak | Oplossing |
|---|---|---|
| Pomp start niet. | Geen stroomvoorziening. Stroomkabel beschadigd. Motoroverbelastingsbeveiliging geactiveerd. | Controleer de stroomaansluiting en het stopcontact. Inspect cable for damage; replace if necessary (by qualified personnel). Disconnect power, allow motor to cool, then reconnect. |
| De pomp draait wel, maar er komt geen water uit. | Intake blocked. De afvoerslang is geknikt of verstopt. Airlock in pump. | Disconnect power, clear intake. Check and clear discharge hose. Briefly lift and lower the pump while submerged to release trapped air. |
| Verminderde pompcapaciteit. | Gedeeltelijke blokkade. Impeller worn. | Disconnect power, clean pump intake and impeller area. Neem contact op met de klantenservice voor hulp. |
| Pomp stopt onverwacht. | Overheating due to low water level or blockage. Elektrisch defect. | Disconnect power, check water level and clear blockages. Allow to cool. Als het probleem zich blijft voordoen, neem dan contact op met de klantenservice. |
If the problem persists after attempting these solutions, please contact Sicce customer support.
7. Technische specificaties
Detailed specifications for the Sicce Ultrazero Flat Sucking Pump, Model 925607:
| Specificatie | Waarde |
|---|---|
| Merk | Sicce |
| Modelnummer | 925607 |
| Max. Delivery Rate (Flow Rate) | 3000 l/u |
| Max. Leveringshoogte | 3.1 minuten |
| Power Consumption (P1) | 80 W |
| Bedrijfsvolumetage | 220-240 V / 50 Hz |
| Conductor Length (Power Cable) | 10 m (three-core, indoor and outdoor use) |
| Drukverbinding | 26.44 mm (3/4") AG |
| Diameter van de slangaansluiting | 20 mm (3/4") |
| Max. Solids Size | 3mm |
| Restwaterniveau | Down to 2-3 mm |
| Productafmetingen (ongeveer) | 140 mm (Diameter) x 160 mm (Height) / 5.5" x 6.3" |
| Artikelgewicht | 2.6 kg (5.72 lbs) |
| Vlotterschakelaar | Nee |
| Overbelastingsbeveiliging | No (Internal thermal protection may exist, but no external reset) |
| Oorsprong | Gemaakt in Italië |

Figure 8: Technical drawing illustrating the pump's dimensions and 3/4" GAS connection.
8. Garantie en ondersteuning
For warranty information or technical support regarding your Sicce Ultrazero Flat Sucking Pump, please contact Sicce customer service. Keep your purchase receipt and model number (925607) handy when contacting support.
Fabrikant: Ebara
Merk: Sicce
For further assistance, visit the official Sicce webwebsite of neem contact op met uw lokale distributeur.





