Invoering
The Leviton 8215-PLC is a 15 Amp, 125 Volt, NEMA 5-15P, 2-pole, 3-wire, straight blade grounding plug designed for hospital grade applications. This transparent plug features a power indication LED, allowing for visual confirmation of power presence. Constructed with a super tough nylon body and solid brass blades and contacts, it offers durability, superior conductivity, and resistance to impact, abrasion, and chemicals.
Image: The Leviton 8215-PLC Hospital Grade Plug, transparent with a green power indicator.
Veiligheidsinformatie
WAARSCHUWING: To avoid fire, shock, or death, always turn off power at the circuit breaker or fuse box before wiring. This device must be installed in accordance with all national and local electrical codes. If you are unsure about any part of these instructions, consult a qualified electrician.
- Always disconnect power before inspecting or working on electrical connections.
- Zorg ervoor dat alle draadverbindingen goed vastzitten en goed geïsoleerd zijn.
- Do not use this plug with damaged or frayed cords.
- Dit product bevat chemicaliën waarvan de staat Californië heeft vastgesteld dat ze kanker en geboorteafwijkingen of andere reproductieve schade kunnen veroorzaken (waarschuwing volgens Proposition 65). Was uw handen na gebruik.
Instellen en installeren
This section provides instructions for properly wiring the Leviton 8215-PLC plug to a power cord. Ensure the power cord is appropriate for the intended application and current rating.
Benodigde gereedschappen:
- Kruiskopschroevendraaier
- Wire strippers
- Utility knife (optional, for outer jacket)
Bedrading instructies:
- Bereid het snoer voor: Carefully strip the outer jacket of your power cord to expose approximately 1.5 to 2 inches of the insulated wires (typically black, white, and green/bare copper). Then, strip about 1/2 inch of insulation from the ends of the black (hot), white (neutral), and green/bare copper (ground) wires.
- Disassemble the Plug: Unscrew the assembly screws on the plug body to separate the front and back sections. Slide the back cover and cord clamp components onto the power cord in the correct orientation.
- Sluit de draden aan: The Leviton 8215-PLC features internal wiring chambers designed to isolate individual conductors. Connect the wires to the appropriate terminals:
- Groene/blanke koperdraad: Maak verbinding met de groente (grounding) screw terminal.
- Witte draad: Maak verbinding met de zilver (neutral) screw terminal.
- Zwarte draad: Maak verbinding met de messing (hot) screw terminal.
- Secure the Cord Clamp: Position the cord clamp around the power cord and tighten the screws to provide a secure grip without damaging the cord's outer jacket. This prevents strain on the wire connections.
- Reassemble the Plug: Carefully align the front and back sections of the plug, ensuring no wires are pinched. Securely fasten the assembly screws.
Afbeelding: Close-up view of the internal wiring chambers, showing isolated conductors and screw terminals.
Image: The plug's cord clamp mechanism, designed to secure the power cord and prevent strain.
Gebruiksaanwijzing
Once properly wired, the Leviton 8215-PLC plug is ready for use.
- Aansluiten op stroom: Insert the plug firmly into a compatible 125V, 15A NEMA 5-15R receptacle.
- Verify Power Indication: The long-life LED bulb on the transparent body of the plug will illuminate green when power is present at the device. This provides a quick visual confirmation that the circuit is live and the plug is receiving power.
- Loskoppelen: To disconnect, grasp the plug body firmly and pull it straight out from the receptacle. Do not pull by the cord.
Onderhoud
Regular inspection and basic maintenance can help ensure the longevity and safe operation of your Leviton 8215-PLC plug.
- Periodieke inspectie: Regularly check the plug and cord for any signs of damage, such as cracks, frayed insulation, bent blades, or discoloration. If any damage is observed, discontinue use and replace the plug or cord as necessary.
- Schoonmaak: Disconnect the plug from the power source before cleaning. Wipe the exterior of the plug with a dry, clean cloth. Do not use liquid cleaners or solvents, as these may damage the material or internal components.
- Verbindingscontrole: If the plug is frequently moved or subjected to stress, periodically check the tightness of the assembly screws and cord clamp screws to ensure secure connections.
Probleemoplossing
If you encounter issues with your Leviton 8215-PLC plug, refer to the following troubleshooting steps:
- LED-indicator brandt niet:
- Ensure the plug is fully inserted into a live receptacle.
- Check the circuit breaker or fuse for the outlet to ensure power is supplied.
- Verify the wiring connections inside the plug are secure (refer to Setup and Installation).
- Inspecteer het netsnoer op eventuele schade.
- Loose Connection or Intermittent Power:
- Disconnect power and re-open the plug to check all wire terminal screws for tightness.
- Ensure the cord clamp is securely tightened to prevent strain on the internal connections.
- Fysieke schade: If the plug body, blades, or cord show signs of physical damage, replace the plug immediately.
Specificaties
| Modelnummer | 8215-PLC |
| Amptijdperk | 15 Amps |
| Deeltage | 125 Volt |
| NEMA-configuratie | 5-15P |
| Polen/Draden | 2 Pole, 3 Wire Grounding |
| Productkwaliteit | Ziekenhuiskwaliteit |
| Materiaal | Super Tough Nylon (Body), Thermoplastic (Back Cover) |
| Kleur | Transparant |
| Stroomindicatie | LED-lamp |
| Goedkeuringen | UL 498, CSA C22.2, NOM 057 |
| Artikelgewicht | 0.01 ons |
| Productafmetingen | 9.38 x 7.13 x 9 inch |
Garantie-informatie
This Leviton product is covered by the manufacturer's limited lifetime warranty. For detailed information regarding warranty terms, conditions, and registration, please refer to the official Leviton website or contact Leviton customer service directly. Keep your proof of purchase for warranty claims.
Klantenservice
For technical assistance, product inquiries, or further support, please visit the official Leviton website or contact their customer service department. Contact information can typically be found on the Leviton weblocatie of productverpakking.
Leviton Webwebsite: www.leviton.com