1. Inleiding
This manual provides essential information for the safe and effective use of your Eiko DT50/35/RS 50W 2G11 Compact Fluorescent Halogen Bulb. Please read these instructions carefully before installation and retain for future reference.
The Eiko DT50/35/RS is a 50-watt compact fluorescent (CFL) bulb, also referred to as a compact fluorescent halogen bulb, featuring a Duo-Tube design and a 2G11 base. It produces a 3500K cool white light with 4300 lumens brightness, suitable for various lighting applications.

Figure 1: Eiko DT50/35/RS 50W 2G11 Compact Fluorescent Halogen Bulb. This image shows the elongated, dual-tube design of the bulb with its 2G11 base at the bottom.
2. Veiligheidsinstructies
WARNING: To prevent electric shock or burns, always turn off the power supply before installing or replacing the bulb.
- Zorg ervoor dat het armatuur geschikt is voor het wattage van de lamp.tage (50W).
- Do not use with dimmers unless explicitly stated as compatible.
- Handle the bulb by its base to avoid touching the glass, as oils from skin can reduce bulb life.
- If the bulb breaks, ventilate the room and carefully clean up the broken glass and mercury according to local regulations.
- Buiten bereik van kinderen houden.
3. Installatie en installatie
- Schakel de stroom uit: Locate the light fixture's power switch and turn it off. For added safety, turn off the circuit breaker controlling the fixture.
- Verwijder de oude lamp (indien van toepassing): If replacing an existing bulb, allow it to cool completely before carefully removing it from the fixture.
- Identify Base Type: Confirm your fixture uses a 2G11 base. The Eiko DT50/35/RS bulb has a 2G11 4-pin base.
- Nieuwe lamp installeren: Align the four pins of the Eiko DT50/35/RS bulb with the corresponding slots in the fixture's 2G11 socket. Gently push the bulb straight into the socket until it is firmly seated. Do not force the bulb.
- Herstel de stroom: Once the bulb is securely installed, turn the circuit breaker back on, then turn on the light switch.

Figure 2: Diagram of a 2G11 base. This illustration shows the four-pin configuration of the 2G11 lamp base, indicating its shape and pin arrangement for proper insertion.
4. Gebruiksaanwijzing
The Eiko DT50/35/RS bulb operates like a standard fluorescent lamp. Once installed in a compatible fixture and power is supplied, it will illuminate when the fixture's switch is turned on.
- Eerste warming-up: Fluorescent bulbs may take a few moments to reach full brightness, especially in colder environments.
- In-/uitschakelen: Frequent switching on and off can reduce the lifespan of fluorescent bulbs. It is recommended to leave the light on for longer periods when possible.
5. Onderhoud
- Schoonmaak: Zorg ervoor dat de stroom is uitgeschakeld en de lamp is afgekoeld voordat u hem schoonmaakt. Veeg de lamp voorzichtig af met een zachte, droge, pluisvrije doek. Gebruik geen vloeibare reinigingsmiddelen of schurende materialen.
- Vervanging: Replace the bulb when it reaches the end of its life (flickering, dimming, or failure to light). Always turn off the power before replacing.
- Beschikbaarheid: This compact fluorescent bulb contains a small amount of mercury. Dispose of it according to local, state, and federal regulations. Many retailers and municipalities offer recycling programs for CFLs. Do not dispose of in regular household trash.
6. Probleemoplossing
| Probleem | Mogelijke oorzaak | Oplossing |
|---|---|---|
| Lampje brandt niet. | Geen stroom naar het armatuur. Lamp is niet goed geplaatst. De lamp is defect of aan het einde van zijn levensduur. Fixture ballast is faulty. | Controleer de hoofdschakelaar en de stroomonderbreker. Turn off power, re-seat bulb firmly. Lamp vervangen. Raadpleeg een gekwalificeerde elektricien. |
| Lamp flikkert. | De lamp is bijna aan het einde van zijn levensduur. Incompatibele dimmer. Losse verbinding. Cold environment. | Lamp vervangen. Remove dimmer or replace with compatible bulb/fixture. Turn off power, check bulb seating. Allow time for warm-up. |
| De lamp brandt zwak. | De lamp is bijna aan het einde van zijn levensduur. Onjuist wattage for fixture. | Lamp vervangen. Ensure fixture and bulb wattage wedstrijd. |
7. Specificaties
| Functie | Detail |
|---|---|
| Merk | Eiko |
| Modelnummer | DT50/35/RS |
| Lichttype | Compact Fluorescent Halogen (CFL) |
| Wattage | 50 Watt |
| Basistype | 2G11 (4-polig) |
| Kleurtemperatuur | 3500 Kelvin (koel wit) |
| Helderheid | 4300 Lumen |
| Vorm | T4 (Duo-Tube) |
| Afmetingen | Ongeveer 1 x 1 x 2.7 inch |
| Artikelgewicht | 3.2 ons |
| Materiaal | Wolfraam |
8. Garantie en ondersteuning
Specific warranty information for Eiko products may vary. Please refer to the original product packaging or the official Eiko website for the most current warranty details.
For technical support or further inquiries, please contact Eiko customer service through their official channels. Contact information can typically be found on the manufacturer's weblocatie of productverpakking.
Fabrikant: Eiko
Onderdeelnummer: DT50/35/RS
UPC-nummer: 031293493040