SAMSON R5a

Samson Rubicon R5a Active Ribbon Studio Monitors User Manual

Model: R5a

Invoering

The Samson Rubicon R5a Active Ribbon Studio Monitors are designed to provide accurate and natural sound reproduction for professional audio environments. This manual provides essential information for the proper setup, operation, and maintenance of your R5a monitors.

Each R5a monitor features a bi-amplified design, delivering 50 watts to a 5-inch inverted cone low-frequency driver and 25 watts to a 2-inch Velocity Ribbon high-frequency transducer. The monitors are housed in a shelf-ported wood enclosure and offer balanced 1/4-inch and XLR input connections. A 4-segment high-frequency lift control allows for precise adjustment of the ribbon tweeter output.

Belangrijke veiligheidsinstructies

Please read these instructions carefully before operating your Samson Rubicon R5a monitors. Keep this manual for future reference.

Inhoud van het pakket

Controleer of uw pakket de volgende items bevat:

Instellen

Plaatsing

Proper placement of your studio monitors is crucial for accurate sound reproduction. Position the monitors to form an equilateral triangle with your listening position. The tweeters should be at ear level. Avoid placing monitors directly against walls or in corners, as this can exaggerate bass frequencies.

Samson Rubicon R5a Studio Monitor front view

Afbeelding: Voorzijde view of a Samson Rubicon R5a Active Ribbon Studio Monitor. It shows the 5-inch woofer, the 2-inch ribbon tweeter, and the Samson logo.

Verbindingen

The Rubicon R5a monitors offer balanced 1/4-inch and XLR input connections. Use high-quality shielded cables to connect your audio source (e.g., audio interface, mixer) to the monitors.

  1. Ensure both the monitors and your audio source are powered off before making any connections.
  2. Connect the audio output from your source to the XLR or 1/4-inch input on each R5a monitor.
  3. Connect the supplied power cables to the IEC power inlets on the rear of each monitor and then to a suitable AC power outlet.
  4. Once all connections are secure, you can proceed to power on your equipment. It is recommended to power on your audio source first, then the monitors. When powering off, turn off the monitors first, then the audio source.

Gebruiksaanwijzing

Aan/uit

Locate the power switch on the rear panel of each monitor. Flip the switch to the "ON" position to power on the monitor. An indicator light on the front panel will illuminate. To power off, flip the switch to the "OFF" position.

Volumeregeling

Each R5a monitor has a volume control knob on the rear panel. Start with the volume set to a low level before playing audio. Gradually increase the volume to your desired listening level. It is generally recommended to control the overall system volume from your audio source (e.g., audio interface, mixer) and use the monitor's volume control for fine-tuning or balancing.

High-Frequency Lift Control

The R5a monitors feature a 4-segment high-frequency lift control. This allows you to adjust the output level of the ribbon tweeter to compensate for room acoustics or personal preference. Experiment with the different settings to find the optimal balance for your listening environment.

The settings typically include:

Onderhoud

To ensure the longevity and optimal performance of your Samson Rubicon R5a monitors, follow these maintenance guidelines:

Probleemoplossing

ProbleemMogelijke oorzaakOplossing
No sound from monitor.
  • Monitor niet ingeschakeld.
  • Stroomkabel losgekoppeld.
  • Audiokabel losgekoppeld of defect.
  • Volume zachter gezet.
  • De audiobron verzendt geen signaal.
  • Check power switch and indicator light.
  • Zorg ervoor dat de stroomkabel stevig is aangesloten op de monitor en het stopcontact.
  • Check audio cable connections; try a different cable.
  • Increase monitor volume and audio source volume.
  • Verify audio source is playing and outputting signal.
Vervormd geluid.
  • Ingangsniveau te hoog.
  • Monitorvolume te hoog.
  • Defecte kabel.
  • Reduce output level from audio source.
  • Reduce monitor volume.
  • Probeer een andere audiokabel.
Hum or buzz.
  • Grond lus.
  • Niet-afgeschermde kabels.
  • Interferentie van andere elektronica.
  • Ensure all equipment is plugged into the same electrical circuit or use a ground loop isolator.
  • Use balanced (XLR or TRS) cables.
  • Move monitors away from power supplies, computers, or other noisy devices.

If the problem persists after trying these solutions, please contact Samson customer support or a qualified service technician.

Specificaties

FunctieDetail
ModelnaamRubicon R5a
LuidsprekertypeActive Ribbon Studio Monitor
Laagfrequent stuurprogramma5-inch inverted cone
Hoogfrequente transducer2-inch Velocity Ribbon
LF Amplifier Vermogen50 Watt
HF Amplifier Vermogen25 Watt
Totaal uitgangsvermogen75 Watt (Bi-amped)
ConnectiviteitstechnologieXLR, 1/4-inch (balanced)
EnergiebronElektrische kabel
BehuizingstypeShelf-ported wood enclosure
Hoogfrequente regeling4-segment lift control
UPC809164005148

Garantie-informatie

Samson Technologies warrants its products to be free from defects in materials and workmanship for a period of one (1) year from the date of original purchase. This warranty is non-transferable and applies only to the original purchaser.

This warranty does not cover damage resulting from accident, misuse, abuse, alteration, or unauthorized service. For full warranty terms and conditions, please refer to the official Samson webwebsite of neem contact op met de klantenservice.

Klantenservice

For technical support, service, or warranty inquiries, please contact Samson Customer Service:

When contacting support, please have your product model (Rubicon R5a) and serial number available.

Gerelateerde documenten - R5a

Preview Samson MediaOne M30 actieve studiomonitoren - Gebruikershandleiding
Gebruikershandleiding voor de Samson MediaOne M30 Powered Studio Monitors, met belangrijke veiligheidsinformatie, functies, een snelstartgids, installatie-instructies en specificaties.
Preview Samson Q7 Dynamische Microfoon Gebruikershandleiding - Kenmerken, Specificaties en Gebruik
Uitgebreide gids voor de Samson Q7 Neodymium dynamische microfoon, met informatie over functies, technische specificaties, microfoonplaatsing, connectiviteit en gebruiksrichtlijnen voor zangers en artiesten.
Preview Gebruikershandleiding voor de Samson MediaOne BT Powered Studio Monitors - Installatie, functies, specificaties
Uitgebreide gebruikershandleiding voor Samson MediaOne BT actieve studiomonitoren, met informatie over functies, installatie, positionering, specificaties en veiligheidsvoorschriften voor de modellen M30BT en M50BT.
Preview Samson MediaOne BT Powered Studio Monitors Owner's Manual
Comprehensive owner's manual for Samson MediaOne BT (MX3BT and MX5BT) powered studio monitors with Bluetooth. Learn about features, setup, pairing, positioning, specifications, and safety guidelines.
Preview Samson Resound HD-serie: Professionele 2-weg luidsprekersystemen - Gebruikershandleiding
Uitgebreide gebruikershandleiding voor de Samson Resound HD-serie professionele 2-weg luidsprekersystemen. Bevat informatie over functies, componenten, installatie, bedrading, specificaties en veiligheidsinstructies voor de modellen RS10HD, RS12HD, RS15HD, RS215HD, RS10mHD, RS12mHD en RS15mHD.
Preview Samson C01 Studio Condensatormicrofoon: Gebruikershandleiding, kenmerken en bediening
Dit document biedt uitgebreide informatie over de Samson C01 Studio Condensatormicrofoon. Het bevat een introductie tot het product, gedetailleerde kenmerken en bedieningsinstructies, inclusief voeding, polaire patronen, microfoonplaatsing, signaalsterkte-instelling en technieken voor popreductie. Het bevat ook instructies voor het monteren van de microfoon op een statief en het gebruik van de optionele SP01 shockmount.