SINOTIMER TM630A

SINOTIMER TM630A 12V DC Programmable Digital Timer Switch

Gebruiksaanwijzing

Invoering

The SINOTIMER TM630A is a compact, programmable digital timer switch designed to automatically control various electrical equipment by switching them on and off at preset times. This device is suitable for a wide range of applications, including controlling streetlights, neon signs, lamps, water heaters, air conditioners, billboards, electric cookers, boosters, sprayers, bottlers, preheaters, agriculture facilities, and broadcasting equipment. It features a built-in battery to retain programmed settings during power failures, ensuring reliable operation. The TM630A is built with a high-accuracy CMOS chip, offers strong anti-jamming capabilities, and is simple to set up and operate. It conforms to IEC 60367 standards and is CE certified.

Specificaties

FunctieSpecificatie
ModelTM630A (also TM630A-4)
TypeMini Digital Timer Switch
MerknaamSINOTIMER
GebruikTimer Switch
Stroomvoorziening12V gelijkstroom/wisselstroom
Uitvoer12 V voltage uitgang
Stroomverbruik3.5 VA (MAX) / 4.5 VA (MAX)
WeergaveLCD
Schakelcontact1 changeover switch (1NO)
Capaciteit30A 250V AC (5000 Watt / 30 Amps)
Programma's16 ON/OFF settings per day or week
Programming Combinations15 Groepen
Mini Interval1 minuut
Timerbereik1 minuut tot 168 uur
Temperatuurbereik-20°C tot +50°C
Hysterese2 sec/dag (bij 25°C)
Gemiddelde fout1 sec/24h (at 25°C)
Auto Time Error Correction+/- 30 sec, weekly
InstallatieDIN RAIL or Screw mounted
Afmetingen98x55x40mm
Gewicht0.15 kg
Inside Battery1.2V (rechargeable, for memory backup)
Black-out Memory Retention60 dagen
CertificatenCE, RoHS, EMC, LVD

Instellen

1. Installatie

The TM630A timer switch can be installed either on a DIN rail or screw-mounted. Ensure the installation location is dry, well-ventilated, and within the specified temperature range (-20°C to +50°C).

2. Bedradingsschema

Refer to the following wiring diagram for proper connection. Ensure all connections are secure and comply with local electrical codes. This diagram shows the connections for the 12V DC/AC input and the load output.

Wiring diagram for SINOTIMER TM630A timer switch, showing power input and load output connections.
Figure 1: TM630A Wiring Diagram. Connect the 12V DC/AC power supply to the input terminals (L, N) and the load to the output terminals.

The timer has two input terminals for power (typically marked L and N for AC, or + and - for DC) and two output terminals for the load.

3. Eerste inschakeling

Upon initial power-up or after extended storage, the internal 1.2V rechargeable battery may be low. Connect the timer to its power supply (12V DC/AC) for a few hours to allow the internal battery to charge. This battery maintains the programmed settings during power outagen.

Gebruiksaanwijzing

1. Knopfuncties

Familiarize yourself with the buttons on the front panel:

Voorkant view of the SINOTIMER TM630A timer switch, highlighting the buttons and LCD display.
Figure 2: TM630A Front Panel with Buttons.
  • C/R (Annuleren/Terugroepen): Clears current settings or recalls saved programs.
  • D+ (Dag): Adjusts the day of the week.
  • H+ (uur): Past het uur aan.
  • M+ (Minuut): Past de minuut aan.
  • P (Program/Timer): Opent de programmeermodus.
  • KLOK: Used in combination with D+, H+, M+ to set the current time and day.
  • HANDMATIG: Manually switches the output ON/OFF or sets to AUTO mode.

2. Setting the Present Time and Day

To set the current time and day of the week:

  1. Houd de KLOK knop.
  2. Terwijl je vasthoudt KLOK, druk op UUR om het huidige uur in te stellen.
  3. Terwijl je vasthoudt KLOK, druk op MINUUT om de huidige minuut in te stellen.
  4. Terwijl je vasthoudt KLOK, druk op DAG om de huidige dag van de week in te stellen.

3. Programmeren van AAN/UIT-tijden

The timer supports up to 16 ON/OFF programs per day or week. Follow these steps to set your desired schedules:

Programming instructions table for the timer switch, showing steps for setting time and ON/OFF programs.
Figure 3: Programming Method Table (English section).
  1. Druk op de TIJDKLOK (P) button once to enter the 1st ON time setting. The display will show "1 ON".
  2. Pers UUR, MINUUT, En DAG buttons to set the desired time and day(s) for the 1st ON event.
    • DAG button allows selecting various combinations of days (e.g., MO, TU, WE, TH, FR, SA, SU; MO, TU, WE, TH, FR; SA, SU; MO, WE, FR; TU, TH, SA; MO, TU, WE; TH, FR, SA; MO, WE, FR, SA; MO, TU, WE, TH, FR, SA, SU).
  3. Druk op de TIJDKLOK (P) button again. The display will show "1 OFF".
  4. Pers UUR, MINUUT, En DAG buttons to set the desired time and day(s) for the 1st OFF event.
  5. Repeat steps 1-4 for additional ON/OFF programs (up to 16 pairs).
  6. Druk op om de programmeermodus te verlaten KLOK knop.

4. Handmatige opheffing

De HANDMATIG button allows you to override the programmed settings temporarily or permanently:

  • Pers HANDMATIG repeatedly to cycle through modes: ON (always on), OFF (always off), and AUTO (follows programmed schedule).
  • In AUTO mode, the timer will execute the programmed ON/OFF events.

Onderhoud

1. Interne batterij

The TM630A includes a 1.2V rechargeable internal battery. This battery automatically recharges when the timer is connected to its power supply. It is designed to retain your programmed settings for up to 60 days during power outages. If the timer has been stored for a long period without power, allow it to charge for several hours before programming to ensure full memory retention.

2. Schoonmaken

To clean the timer, gently wipe the exterior with a soft, dry cloth. Do not use abrasive cleaners, solvents, or immerse the device in water.

Probleemoplossing

  • Display is leeg: Check if the timer is receiving power (12V DC/AC). If it has been without power for an extended period, the internal battery may be fully discharged. Connect to power and allow it to charge.
  • Programma's worden niet uitgevoerd:
    • Zorg ervoor dat de timer is ingeschakeld AUTO mode (check the display for "AUTO"). Press the HANDMATIG button to cycle to AUTO mode if necessary.
    • Controleer of de huidige tijd en dag correct zijn ingesteld.
    • Controleer of de AAN/UIT-programma's correct zijn ingevoerd en ingeschakeld.
  • Time drift: The timer has an auto time error correction of +/- 30 seconds weekly. Significant deviations may indicate an issue with the power supply or internal components.
  • Loss of programs after power outage: While the internal battery provides memory retention for up to 60 days, prolonged power outages or a depleted internal battery can lead to program loss. Ensure the internal battery is adequately charged.

Gebruikerstips

  • For critical applications, consider testing your programmed schedules after initial setup to ensure they function as expected.
  • Profiteer ervantage of the 15 programming group combinations to create complex weekly schedules for different days or sets of days.
  • The manual override function is useful for temporary changes without altering your saved programs.
  • Given its wide application range, this timer is highly versatile. Consider using it for automating garden irrigation, aquarium lighting, or even charging cycles for low-voltage-apparaten.

Garantie en ondersteuning

The SINOTIMER TM630A timer switch is certified with CE, RoHS, EMC, and LVD standards, indicating compliance with relevant health, safety, and environmental protection directives.

For warranty information, technical support, or service inquiries, please contact your original point of purchase or the manufacturer directly. The product package includes a manual in Russian, Portuguese, and English languages for detailed guidance.

Documents - SINOTIMER – TM630A
[PDF] Gebruiksaanwijzing
630 曲2023 4 26 hx3 User manual SINOTIMER TM630A 12V DC Input 7 Days Programmable 24hrs Mini Timer Switch Time Relay Output Load High Power 30A 230VAC Din Rail Digital Timers S690423bd7a374fd3aaf4a8fcb31044b20 ae01 alicdn kf ae pic a1 aliexpress media
2022 03 630 PRESS S 4 TIMES TO UNLOCK TM630A PRESS C/R 4 TIMES TO UNLOCK TM630S K: 85-265VAC 10/30AMP 28 10/30AMP 28 10/30AMP 28 ...
score: 31 filegrootte: 2.38 M pagina's: 2 documentdatum: 2023-04-26
[PDF] Gebruiksaanwijzing
630 曲 202203630 hx3 User manual SINOTIMER TM630SAC 220V DC 12V Second Setting Digital Timer Switch 24hr 7 Days Weekly Programmable Time Relay Voltage Output High Load Power 30A TM630SSed87796800e14f9a95c3277c745d4e13aae01 alicdn kf Sed87796800e14f9a95c3277c745d4e13a |||
2022 03 630 PRESS S 4 TIMES TO UNLOCK TM630A PRESS C/R 4 TIMES TO UNLOCK TM630S K: 85-265VAC 10/30AMP 28 10/30AMP 28 10/30AMP 28 ...
score: 25 filegrootte: 2.4 M pagina's: 2 documentdatum: 2022-03-20
SINOTIMER TM-630A/TM-630S Digitale Timer: Kenmerken en Specificaties
Gedetailleerde technische specificaties en kenmerken van de digitale programmeerbare timers SINOTIMER TM-630A en TM-630S, inclusief voeding, tijdbereik, afmetingen en bedrading.
score: 15 filegrootte: 445.58 K pagina's: 1 documentdatum: 2024-09-07