U.S. Solid USS-DBS87-110G

U.S. Solid 0.001 g Precision Balance Instruction Manual

Model: USS-DBS87-110G

Merk: US Solid

Invoering

This manual provides comprehensive instructions for the setup, operation, maintenance, and troubleshooting of your U.S. Solid 0.001 g Precision Balance. Please read this manual thoroughly before using the device to ensure proper function and accurate measurements. This analytical balance is designed for precise weighing in laboratory and industrial environments.

Wat zit er in de doos?

  • Main Body of the Precision Balance
  • Weegpan
  • Tochtscherm
  • Stroomkabel
  • Kalibratiegewicht
  • Gebruiksaanwijzing
U.S. Solid Precision Balance with included accessories: main unit, power adapter, calibration weight, and weighing pan.

Figure 1: Components included with the U.S. Solid Precision Balance.

Veiligheidsmaatregelen

  • Always operate the balance on a stable, level surface.
  • Avoid placing the balance near strong electromagnetic fields, vibrations, or air currents.
  • Do not overload the balance beyond its maximum capacity of 110 g to prevent damage.
  • Use only the provided UL-certified power cable.
  • Keep the balance clean and free from dust and corrosive substances.
  • Do not attempt to disassemble or repair the balance yourself. Contact qualified service personnel.

Instellen

1. Uitpakken en plaatsen

Carefully remove all components from the packaging. Place the balance on a sturdy, level, and vibration-free workbench, away from direct sunlight, heat sources, and strong air currents (e.g., air conditioning vents).

2. Montage

  • Place the weighing pan onto the pan support in the center of the balance.
  • Assemble the draft shield around the weighing pan. Ensure all panels are securely in place to protect against air disturbances.
Gehoekt view of the U.S. Solid Precision Balance with the draft shield and weighing pan assembled.

Figure 2: Assembled balance with draft shield.

3. Nivellering

The balance must be perfectly level for accurate measurements. Adjust the adjustable feet at the bottom of the balance until the bubble in the spirit level (located on the front or side of the balance) is centered.

Diagram showing horizontal adjustment of leveling feet, environmental stability, warm-up time, and calibration process for the precision balance.

Figure 3: Leveling the balance using adjustable feet and the bubble level.

4. Stroomaansluiting

Connect the UL-certified power cable to the 6V DC input port on the rear of the balance and then plug it into a suitable power outlet.

5. Warm-up Time

After connecting to power, allow the balance to warm up for at least 30 minutes before use. This stabilizes the internal components and ensures optimal accuracy.

Gebruiksaanwijzing

Van dichtbij view of the U.S. Solid Precision Balance control panel with buttons for Power, Set, Tare, Cal, and Mode.

Figure 4: Control panel of the precision balance.

1. Aan/uit

  • Druk op de STROOM button to turn the balance on.
  • Houd de STROOM button to turn the balance off.

2. Eenheidsconversie

Druk op de MODUS button to cycle through available weighing units: grams (g), carats (ct), ounces (oz), and grains (gn). The selected unit will be displayed on the LCD.

Diagram illustrating the available measuring units: grams (g), grains (gn), ounces (oz), and carats (ct).

Figure 5: Available weighing units.

3. Tarrafunctie

To subtract the weight of a container, place the empty container on the weighing pan and press the 0/T (Tare) button. The display will reset to zero, allowing you to measure only the net weight of the contents.

4. Kalibratie

Regular calibration ensures the accuracy of your balance. It is recommended to recalibrate if the balance has been moved or if accuracy is critical. Refer to the specific calibration procedure in the full manual for detailed steps. Generally, this involves pressing the KAL button and following on-screen prompts using the provided calibration weight.

5. Onderdelentelfunctie

The balance includes a piece-counting function for counting multiple items of uniform weight. To use this feature:

  • Place a known number of sample pieces (e.g., 10, 20, 50, or 100) on the pan.
  • Druk op de SET button and follow the instructions to input the sample hoeveelheid.
  • Zodra de sample is registered, remove it and place the bulk quantity of items on the pan. The display will show the total count.
Diagram illustrating the piece counting function of the precision balance.

Figure 6: Piece counting function.

6. RS232 Data Transfer

The balance is equipped with an RS232 serial port for data transfer to a computer or other compatible device. Connect a compatible RS232 cable (not included) to the port on the rear of the balance. Refer to your software documentation for data acquisition procedures.

Achterkant view of the U.S. Solid Precision Balance showing the RS232 serial port and 6V DC power input.

Afbeelding 7: Achter view with RS232 port.

7. Overbelastingsbeveiliging

The balance features an overload alarm function. If the weight on the pan exceeds the maximum capacity (110 g), an alarm will sound, and an error message may appear on the display. Immediately remove excess weight to prevent damage to the weighing sensor.

Onderhoud

1. Schoonmaken

Clean the balance regularly with a soft, damp cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the display or housing. Ensure no liquids enter the internal components.

2. Opslag

When not in use for extended periods, store the balance in a dry, dust-free environment. It is recommended to keep the draft shield assembled to protect the weighing pan.

Probleemoplossing

ProbleemMogelijke oorzaakOplossing
Onnauwkeurige metingenBalance not level, environmental interference (drafts, vibrations), needs calibration, warm-up time insufficient.Ensure balance is level. Relocate to a stable, draft-free area. Perform calibration. Allow sufficient warm-up time.
Display toont 'EEEE' of 'OVER'Overbelastingstoestand.Remove excess weight immediately. Ensure weight does not exceed 110 g.
Balance does not power onPower cable not connected, power outlet fault, power adapter fault.Check power cable connection. Test power outlet with another device. Contact support if power adapter is suspected faulty.
Piece counting is incorrectOnjuiste sample quantity entered, inconsistent piece weight.Zorg voor de juiste sample quantity is entered during setup. Verify that all pieces have a uniform weight.

Specificaties

FunctieSpecificatie
ModelnummerUSS-DBS87-110G
MerkVS Vast
Capaciteit110 gram
Leesbaarheid0.001 gram (1mg)
Weegeenhedeng, ct, oz, gn
WeergavetypeLCD met achtergrondverlichting
Speciale kenmerkenPiece-counting function, RS232 serial port, Overload protection
StroomvoorzieningUL Certified Power Cord (6V DC)
MateriaalMetal (pan), Plastic ABS (housing)
Productafmetingen10.4 x 13.8 x 14.2 inch
Artikelgewicht3.53 ounces (ongeveer 100 gram)
Diagram showing the dimensions of the U.S. Solid Precision Balance: 7.88 inches width, 10.63 inches depth, and 10.63 inches height.

Figuur 8: Productafmetingen.

Garantie en ondersteuning

For warranty information or technical support, please refer to the warranty card included with your product or visit the official U.S. Solid webwebsite. Bewaar uw aankoopbewijs als aankoopbewijs voor garantieclaims.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.