SINOTIMER TM919B
TM919B 30A Programmable Electronic Timer Switch User Manual
Model: TM919B
1. Inleiding
The SINOTIMER TM919B is a 30A 7-day programmable electronic timer switch designed for automatic control of various electrical equipment. It allows you to set specific ON/OFF times over a 24-hour or 7-day cycle, providing convenience and energy efficiency for applications such as streetlights, lamps, water heaters, air conditioners, and more.
Belangrijkste kenmerken:
- Ideal for household use in DB Boards.
- High capacity: 5000 Watt / 30 Amps.
- Flexible programming: 24 Hours / 7 Days a Week Programmable.
- Automatic time error correction: +/- 30 seconds weekly.
- Multiple programs: Repeat programs with 16 ON/OFF settings.
- Handmatige AAN/UIT-regeling.
2. Product voorbijview

Figuur 1: Voorzijde view of the TM919B timer switch, displaying the LCD screen with time and day, and the array of control buttons including P, D+, H+, M+, RESET, and MANUAL.

Figuur 2: Schuin view of the TM919B timer switch, showing its side profile and the clear protective cover over the buttons.

Figuur 3: Zijkant view of the TM919B timer switch, detailing the wiring terminals (L, N, 1, 2, 3, 4, 5) and product specifications like voltage en huidige beoordelingen.
3. Specificaties
| Parameter | Waarde |
|---|---|
| Temperatuurbereik | -20°C tot +50°C |
| Bedrijfsvolumetage (UI) | 110V |
| Stroomverbruik | 4.5 VA (MAX) |
| Weergave | LCD |
| Schakelcontact | 1 omschakelaar |
| Programma's | 16 ON/OFF settings per day or week |
| Hysterese | 2 sec/dag (bij 25°C) |
| Minimaal interval | 1 minuut |
| Capaciteit | 30A 250V AC |
| Black-out geheugen | 60 dagen |
| Timerbereik | 1 minuut tot 168 uur |
| Gemiddelde fout | 1 second/24 hours (at 25°C) |
| Artikelgewicht | 5.3 ounces (0.2kg) |
| Pakket afmetingen | 3.95 x 3.2 x 2 inch |
| Schermgrootte | 1.5 inch |
4. Installatie en bedrading
The TM919B timer switch is designed for DIN rail mounting, making it suitable for integration into electrical distribution boards. Ensure all power is disconnected before attempting installation.
Bedradingsschema:

Figure 4: Wiring diagram for the TM919B. Terminals 1 and 2 are for power input (L and N). Terminals 3, 4, and 5 are for the output, typically used for NO (Normally Open) and NC (Normally Closed) connections to control the load.
- Stroomverbruik: Connect the live (L) and neutral (N) wires to terminals 1 and 2 respectively. Ensure the voltage matches the timer's specification (110V for this model).
- Belastingsaansluiting: The timer has a single changeover switch.
- Terminal 3: Normally Closed (NC) contact.
- Terminal 4: Common (COM) contact.
- Terminal 5: Normally Open (NO) contact.
- Connect your load (e.g., lamp, motor) between the common terminal (4) and either the NO (5) or NC (3) terminal, depending on whether you want the load to be ON or OFF when the timer is in its default state.
- Securely fasten all wires to prevent loose connections.
- Once wiring is complete, restore power and proceed with programming.
5. Operating Instructions and Programming
The TM919B timer allows for up to 16 ON/OFF programs. Follow these steps to set the current time and program the timer.
Knopfuncties:
- P (Programma): Opent de programmeermodus.
- D+ (Dag): Adjusts the day of the week.
- H+ (uur): Past het uur aan.
- M+ (Minuut): Past de minuut aan.
- HERSTEL: Resets all settings to factory defaults. Use a pointed object to press.
- HANDMATIG: Schakelt tussen de modi AAN, AUTO en UIT.
Huidige tijd instellen:
- Druk op de D+ knop om de huidige dag van de week in te stellen.
- Druk op de H+ knop om het huidige uur in te stellen.
- Druk op de M+ knop om de huidige minuut in te stellen.
- De tijd wordt na enkele seconden inactiviteit automatisch opgeslagen.
Programming ON/OFF Times (Up to 16 Programs):
- Druk op de P Druk één keer op de knop. Op het display verschijnt "1 AAN". Hiermee stel je de eerste inschakeltijd in.
- Pers H+ En M+ to set the desired hour and minute for the first ON event.
- Pers D+ to select the days of the week for this program. Options include: every day, specific days (e.g., MO-FR, MO-SA, SA-SU), or individual days. If you want the same setting every day, you do not need to press D+.
- Druk op de P button again. The display will show "1 OFF". This is for setting the first OFF time.
- Pers H+ En M+ to set the desired hour and minute for the first OFF event.
- Pers D+ again if you need to specify different days for the OFF event, or leave it if it matches the ON event's days.
- Repeat steps 1-6 for programs 2 through 16 (e.g., "2 ON", "2 OFF", etc.).
- Nadat u alle gewenste programma's hebt ingesteld, drukt u op de HANDMATIG button repeatedly until "AUTO" is displayed. This ensures the timer operates according to your programmed schedule.
Handmatige bediening:
Druk op de HANDMATIG knop om door de bedieningsmodi te schakelen:
- OP: The output is continuously ON, overriding programmed settings.
- OFF: The output is continuously OFF, overriding programmed settings.
- AUTO: The timer operates according to the programmed ON/OFF schedules. Ensure the timer is in AUTO mode for automatic operation.
6. Onderhoud
The TM919B timer switch requires minimal maintenance. Keep the device clean and free from dust. Do not expose it to excessive moisture or extreme temperatures. If the display becomes dim or unresponsive, check the power supply. The internal battery provides backup for settings during power outages for up to 60 days.
7. Probleemoplossing
| Probleem | Mogelijke oorzaak | Oplossing |
|---|---|---|
| Timer not turning ON/OFF at programmed times. | Not in AUTO mode; incorrect programming; power issue. | Press MANUAL until "AUTO" is displayed. Review programming steps carefully. Check power supply to the timer. |
| Het scherm is leeg of donker. | No power supply; internal battery low (unlikely for display). | Check power connections. Ensure the timer is receiving power. |
| Tijd en programma's kunnen niet worden ingesteld. | Knoppen reageren niet; apparaat is vastgelopen. | Press the RESET button using a pointed object. This will clear all settings, so you will need to reprogram. |
| Load not switching. | Incorrect wiring; faulty load; timer output issue. | Verify wiring according to the diagram. Test the load independently. If issues persist, contact support. |
8. Garantie en ondersteuning
This SINOTIMER product is covered by a standard manufacturer's warranty against defects in materials and workmanship. For warranty claims or technical support, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.
For further assistance, visit the official SINOTIMER store: SINOTIMER-winkel op Amazon