PASCO scientific PS-2002

PASCO PS-2002 Xplorer GLX Graphing Logger User Manual

Model: PS-2002

1. Inleiding

This manual provides comprehensive instructions for the operation, maintenance, and troubleshooting of the PASCO PS-2002 Xplorer GLX Graphing Logger. The Xplorer GLX is a versatile data acquisition device designed for scientific experimentation and analysis, capable of functioning both as a standalone unit and as a computer interface.

PASCO PS-2002 Xplorer GLX Graphing Logger device

Figuur 1: Voorkant view of the PASCO PS-2002 Xplorer GLX Graphing Logger. This device features a large LCD screen for data display, function buttons (F1-F4) for quick access, a central navigation pad, a numeric keypad for data entry, and a power button at the bottom. The casing is a translucent blue with green accents on the primary control buttons.

2. Belangrijkste kenmerken

The PASCO PS-2002 Xplorer GLX offers a range of features designed for robust data logging and analysis:

  • Geïntegreerde sensoren: Includes 2 temperature sensors, a sound sensor, and a voltage-sensor.
  • Universal Sensor Ports: Four dedicated PASPORT sensor ports for compatibility with over 60 PASPORT sensors.
  • Hoge Sampleng tarief: Capable of a maximum 50,000 Hz sampling rate for precise data capture.
  • Interne opslag: Equipped with 12 MB of built-in flash memory for data storage.
  • Connectiviteit: Two USB ports for connecting to computers, external storage, or peripherals like a mouse and keyboard.
  • Stroom: Powered by a rechargeable 1700 mAH NiMH Battery.
  • Weergave: Large backlit LCD for clear visibility in various lighting conditions.
  • Zelfstandige werking: Functions independently for data collection, analysis, annotation, storage, and printing without a computer.
  • Computerinterface: Can connect to a computer to utilize PASCO Capstone software for advanced analysis.

3. Instellen en eerste gebruik

3.1 Uitpakken en componenten

Controleer bij het uitpakken of alle onderdelen aanwezig zijn:

  • PASCO PS-2002 Xplorer GLX unit
  • Rechargeable 1700 mAH NiMH Battery (pre-installed or separate)
  • USB-kabel (voor opladen en computerverbinding)
  • Stroomadapter (indien meegeleverd)

3.2 De batterij opladen

  1. Connect the USB cable to the GLX unit's USB port.
  2. Connect the other end of the USB cable to a power adapter or a computer's USB port.
  3. Allow the unit to charge fully before first use. The charging indicator will provide status.

3.3 In-/uitschakelen

  • Houd de ingedrukt om in te schakelen Stroom button (usually located at the bottom of the keypad) until the screen illuminates.
  • Om uit te schakelen, houdt u de . ingedrukt Stroom Houd de knop ingedrukt totdat de melding voor afsluiten verschijnt en bevestig dit vervolgens.

3.4 Sensoren aansluiten

The GLX features four universal PASPORT sensor ports. To connect a sensor:

  1. Align the sensor's connector with one of the PASPORT ports on the GLX.
  2. Gently push the sensor into the port until it clicks into place.
  3. The GLX should automatically detect the connected sensor.

4. Gebruiksaanwijzing

4.1 Navigatie

The Xplorer GLX uses an icon-based operating system. Navigation is primarily done using the central directional pad and function buttons (F1-F4).

  • Richtingspad: Use the up, down, left, and right arrows to move between menu items or data points. The center button typically acts as a selection or confirmation button.
  • Functieknoppen (F1-F4): These buttons correspond to on-screen labels and provide quick access to specific functions or menus.
  • ESC-knop: Used to go back to the previous screen or cancel an operation.
  • Numeriek toetsenbord: For entering numerical values or text (using multi-press for letters).

4.2 Gegevensverzameling

  1. Selecteer meting: From the main menu, navigate to the desired measurement setup (e.g., Graph, Digits, Table).
  2. Instellingen configureren: Pas s aanampling rate, duration, and trigger conditions as needed for your experiment.
  3. Start Collection: Druk op de Toneelstuk button (often a green triangle icon) to begin data collection.
  4. Stop Collection: Druk op de Stop button (often a square icon) to end data collection.

4.3 Data Analysis and Review

The GLX allows for basic on-device data analysis:

  • Grafiek View: Display collected data as a graph. Use navigation buttons to zoom or pan.
  • Statistieken: Access statistical tools (mean, min, max, standard deviation) for selected data ranges.
  • Linear Curve Fits: Perform basic linear regression on graphical data.
  • Annotatie: Add text notes or recorded voice messages to data points or entire runs.

4.4 Aansluiten op een computer

For advanced analysis and data management, connect the GLX to a computer:

  1. Ensure PASCO Capstone software is installed on your computer.
  2. Connect the GLX to your computer using a USB cable.
  3. The GLX will be recognized as a device within Capstone, allowing data transfer and real-time monitoring.

5. Onderhoud

5.1 Reinigen

To maintain the device's condition:

  • Veeg de buitenkant van het apparaat af met een zachte, damp lap.
  • Gebruik geen schurende reinigingsmiddelen of oplosmiddelen.
  • Ensure no liquid enters the sensor ports or USB ports.

5.2 Batterijonderhoud

  • Recharge the NiMH battery regularly to maintain its lifespan.
  • Zorg ervoor dat de batterij niet te vaak volledig ontladen wordt.
  • If storing the unit for an extended period, ensure the battery is partially charged (around 50%).

5.3 Opslag

Store the Xplorer GLX in a cool, dry place, away from direct sunlight and extreme temperatures.

6. Probleemoplossing

ProbleemMogelijke oorzaakOplossing
Het apparaat wordt niet ingeschakeld.Batterij is leeg.Connect the unit to a power source using the USB cable and allow it to charge.
Sensor not detected.Sensor not properly connected or faulty.Ensure the sensor is firmly seated in the PASPORT port. Try a different port or sensor if available.
Het scherm is donker of onleesbaar.Backlight setting is low or environmental lighting is poor.Adjust the backlight settings in the system menu. Move to a better-lit environment if necessary.
Data collection stops unexpectedly.Low battery or insufficient memory.Charge the battery. Check available memory and delete old data if needed.

7. Specificaties

FunctieDetail
ModelnummerPS-2002
MerkPASCO wetenschappelijk
Afmetingen (L x B x H)9 x 3.8 x 1.9 inch
Gewicht1.29 pond
Sensorpoorten4 PASPORT sensor ports
Ingebouwde sensoren2 Temperature, Sound, Voltage
Sampling Rate (Max)50,000Hz
Intern geheugen12 MB Flash-geheugen
Connectiviteit2 USB-poorten
EnergiebronRechargeable 1700 mAH NiMH Battery
WeergavetypeLCD met achtergrondverlichting
MateriaalPlastic
OnderhoudsinstructiesSchoonvegen

8. Ondersteuning en garantie

For technical support, product inquiries, or warranty information, please contact PASCO scientific directly. Refer to the official PASCO scientific webVoor de meest actuele contactgegevens en garantievoorwaarden kunt u terecht op de website.

Fabrikant: PASCO

Datum eerste beschikbaarheid: 19 september 2017

© 2024 PASCO scientific. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.