REHAU 13360241001
Rehau Nea H 24 13360241001 Bedrade kamerthermostaat 24V Gebruikershandleiding
Model: 13360241001 | Merk: REHAU
1. Inleiding
This manual provides detailed instructions for the installation, operation, and maintenance of the Rehau Nea H 24 Wired Room Thermostat 24V. This device is designed for controlling the ambient temperature of surface heating systems.
The Rehau Nea H 24 thermostat is CE and VDE approved according to EN 60730-2-9 and EN 60730-1 standards, ensuring reliable and safe operation.
2. Veiligheidsinstructies
- Elektrische veiligheid: Installation and wiring must be performed by a qualified electrician in accordance with local electrical codes and regulations. Ensure the power supply is disconnected before any installation or maintenance work.
- Deeltage: This thermostat operates on 24V. Do not connect it to higher voltage-systemen.
- Omgeving: Stel het apparaat niet bloot aan vocht, extreme temperaturen of direct zonlicht.
- Behandeling: Handle the thermostat with care to avoid physical damage.
- Beschikbaarheid: Dispose of the product and its components responsibly, following local environmental regulations.
3. Inhoud van het pakket
Please check the package contents upon unpacking to ensure all parts are present:
- Rehau Nea H 24 Wired Room Thermostat
- Muurbevestigingsbeugel
- Up to 5 actuators (depending on specific kit/purchase)
- Gebruikershandleiding (dit document)
4. Installatie en installatie
4.1 Montage
The Rehau Nea H 24 thermostat is suitable for mounting on a flush-mounted box or directly on the wall. Choose a location that accurately represents the room's temperature, away from direct heat sources, drafts, or direct sunlight.
4.2 Bedrading
This thermostat uses a wired connection and operates on 24V. It can connect to a maximum of 5 servo motors. Refer to the wiring diagram provided with your heating system or consult a qualified electrician for proper connection. Ensure all connections are secure and insulated.

Figuur 1: Voorzijde view of the Rehau Nea H 24 Wired Room Thermostat. The thermostat is white with a central grey rectangular display. A minus button (-) is located to the left of the display, and a plus button (+) is to the right. The REHAU logo is printed at the bottom center of the unit.
5. Gebruiksaanwijzing
The Rehau Nea H 24 thermostat offers various operating modes and features to manage your surface heating system efficiently.
5.1-bedrijfsmodi
- Automatische modus: The thermostat follows a pre-programmed schedule (if connected to an external digital timer like the Nea timer).
- Normale modus: Handhaaft een comfortabele, ingestelde temperatuur.
- Verminderde modus: Handhaaft een lagere, energiebesparende temperatuur.
- Optional Modes: Additional modes may be available depending on the connected external timer or system configuration.
5.2 Belangrijkste kenmerken
- Temperatuurverlaging: Can be achieved via an external digital timer (e.g., Nea timer) for scheduled energy savings.
- Vorstbeveiligingsfunctie: Automatically activates heating to prevent pipes from freezing if the temperature drops below a set threshold.
- Ventielbeveiligingsfunctie: Periodically cycles the heating valves to prevent them from seizing due to inactivity.
- Datumweergave: The thermostat features a display that can show the current date.
- Temperatuurregeling: Use the '+' and '-' buttons to adjust the desired temperature setpoint.
6. Onderhoud
The Rehau Nea H 24 thermostat requires minimal maintenance.
- Schoonmaak: Wipe the surface of the thermostat with a soft, dry, or slightly damp doek. Gebruik geen schuurmiddelen, oplosmiddelen of chemische sprays, omdat deze de c kunnen beschadigenasing of interne componenten.
- Inspectie: Periodically check the wiring connections for any signs of wear or looseness. Ensure the thermostat is securely mounted.
7. Probleemoplossing
If you encounter issues with your Rehau Nea H 24 thermostat, refer to the following common problems and solutions:
| Probleem | Mogelijke oorzaak | Oplossing |
|---|---|---|
| Thermostat not powering on / No display |
|
|
| Heating not responding to thermostat settings |
|
|
| Onnauwkeurige temperatuurmetingen |
|
|
Note: One user reported a circuit board issue upon initial power-on. This is often related to incorrect wiring or power supply issues rather than a defect in the thermostat itself. Always ensure correct voltage and wiring before powering on.
8. Technische specificaties
| Modelnummer | 13360241001 |
| Merk | REHAU |
| Sollicitatie | Ambient temperature control for surface heating systems |
| Deeltage | 24 Volt |
| Connectiviteitstechnologie | Bedraad |
| Controller-type | Drukknop |
| Type temperatuurregeling: | Programmable (with external timer) |
| Afmetingen (L x H x D) | 88x88x26mm |
| Beschermingsklasse | IP30 |
| Kleur | Front: Signal White (RAL 9016), Back: Anthracite Grey (RAL 7016) |
| Gewicht | 130 gram |
| Max. Servomotors | 5 (connectable) |
| Speciale kenmerken | Date display, Frost protection, Valve protection |
| Certificeringen | CE according to EN 60730-2-9 and EN 60730-1, VDE according to EN 60730-2-9 and EN 60730-1 |
9. Garantie en ondersteuning
Information regarding specific spare parts availability is not provided. For warranty claims, technical support, or service inquiries, please contact REHAU customer service directly or refer to their official webwebsite voor contactgegevens.
It is recommended to keep your purchase receipt as proof of purchase for any warranty-related matters.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.