Beckett 7218510

Beckett 1250 GPH Submersible Water Pump Instruction Manual

Model: 7218510 | Brand: Beckett

Invoering

This manual provides essential information for the safe and efficient operation of your Beckett 1250 GPH Submersible Water Pump. Please read these instructions carefully before installation and use. Retain this manual for future reference.

The Beckett 1250 GPH Submersible Water Pump is designed for circulating water in fountains, ponds, and waterfalls. This magnetic drive pump features a low water shut-off sensor for protection and is suitable for continuous, submerged operation. It is oil-free, making it safe for aquatic life.

Belangrijke veiligheidsinformatie

WARNING: To avoid possible electric shock, special care should be taken since water is used in the use of pond equipment. For each of the following situations, do not attempt repairs yourself. Return the appliance to an authorized service facility for service or discard the appliance.

  • Ensure the pump is always fully submerged in water during operation. Running dry will damage the pump and void the warranty.
  • Gebruik de pomp niet als het netsnoer of de stekker beschadigd is.
  • Do not remove the grounding prong from the power plug.
  • Koppel de pomp altijd los van de stroomvoorziening voordat u onderhouds- of reinigingswerkzaamheden uitvoert.
  • Do not lift the pump by its power cord. Use the molded handle provided.
  • This pump is designed for fresh water use only.
  • Ensure the electrical outlet is a grounded, GFCI-protected receptacle.
  • Houd kinderen en huisdieren uit de buurt van de pomp en het waterornament tijdens gebruik.

This pump is UL Listed for electrical safety.

Inhoud van het pakket

Controleer of alle componenten aanwezig zijn voordat u met de installatie begint:

  • Beckett 1250 GPH Submersible Water Pump with 15 ft. power cord
  • 1-inch ID tubing adapter
Beckett 1250 GPH Submersible Water Pump with power cord and adapter

Image: The Beckett 1250 GPH Submersible Water Pump, showing the pump unit, coiled 15-foot power cord, and the included 1-inch ID tubing adapter.

Disassembled Beckett 1250 GPH Submersible Water Pump components

Afbeelding: Ontploft view of the pump components, including the outer casing, pump body, power cord, and tubing adapter.

Instellen en installeren

  1. Kies locatie: Place the pump in the deepest part of your pond or water feature, ensuring it is fully submerged. The pump is designed for continuous submerged operation.
  2. Bevestig slangen: Connect appropriate 1-inch ID (Inner Diameter) tubing to the pump's outlet using the provided adapter. Secure the tubing with a hose clamp (niet inbegrepen) om lekkages te voorkomen.
  3. Positionering: Use the molded handle to carefully lower the pump into the water. Ensure the pump is stable and not resting on loose debris.
  4. Elektrische aansluiting: Route the 15-foot power cord to a grounded, GFCI-protected electrical outlet. Ensure the cord is not kinked or pinched. Do not plug in the pump until it is fully submerged.
  5. Dompelpomp: Ensure the water level is sufficient to completely cover the pump. The pump features a low water shut-off sensor that will prevent operation if the water level is too low.
  6. Inschakelen: Once the pump is fully submerged and all connections are secure, plug the pump into the GFCI-protected outlet.
Diagram showing pump specifications for small waterfalls

Image: Diagram illustrating the pump's suitability for small waterfalls, indicating 1250 GPH flow, 115V, 60Hz, 50 watts power requirements, and a 15 ft cord length.

Diagram showing average performance and maximum lift for Beckett pumps

Image: Performance chart showing the relationship between pump height and flow rate, with the 1250 GPH pump (FC1200) reaching a maximum lift of 14.8 ft.

Bediening

The Beckett 1250 GPH Submersible Water Pump is designed for continuous operation once properly installed and submerged.

  • Initiële opstart: After plugging in, the pump should begin circulating water immediately. If it does not, ensure it is fully submerged and the power supply is active.
  • Afsluiting bij laag waterpeil: This pump is equipped with a low water shut-off sensor. If the water level drops below the safe operating threshold, the pump will automatically turn off to prevent damage. It will restart automatically once the proper water level is restored.
  • Continue werking: For optimal performance and longevity, ensure the pump remains fully submerged and free from debris.

Onderhoud

Regelmatig onderhoud zorgt voor optimale prestaties en verlengt de levensduur van uw pomp.

  1. Stroom loskoppelen: Haal altijd de stekker van de pomp uit het stopcontact voordat u onderhoudswerkzaamheden uitvoert.
  2. Clean Inlet Screen: Periodically inspect and clean the pump's inlet screen to remove any accumulated debris such as leaves, algae, or sediment. A clogged screen can reduce flow and strain the motor.
  3. Inspecteer de waaier: If flow is reduced after cleaning the screen, the impeller may be obstructed. Carefully remove the pump casing and clean the impeller and its housing.
  4. Winterklaar maken: In freezing climates, remove the pump from the water feature before the first freeze. Clean the pump thoroughly and store it in a frost-free location, submerged in a bucket of water if possible, to keep seals moist.
Onderkant view of Beckett 1250 GPH pump showing inlet screen

Afbeelding: Onderkant view of the Beckett 1250 GPH pump, highlighting the large inlet screen designed to protect against debris.

Probleemoplossing

ProbleemMogelijke oorzaakOplossing
Pump does not start or stops unexpectedly.
  • De pomp krijgt geen stroom.
  • Low water level (low water shut-off activated).
  • Clogged inlet screen or impeller.
  • Damaged impeller or motor.
  • Controleer de stroomaansluiting en het aardlekschakelaarstopcontact.
  • Add water to the feature until the pump is fully submerged and restarts.
  • Clean the inlet screen and impeller.
  • Contact customer support if pump remains inoperable after cleaning and ensuring power/water.
Verminderde waterstroom.
  • Clogged inlet screen.
  • Obstruction in tubing or nozzle.
  • Debris around impeller.
  • Pump operating at too high a lift.
  • Clean the inlet screen.
  • Check and clear tubing/nozzle.
  • Maak de waaier schoon.
  • Ensure the pump is not exceeding its maximum lift capacity (14.8 ft).
Pomp maakt lawaai.
  • Vuil in waaier.
  • De pomp is niet volledig ondergedompeld.
  • Worn impeller or bearings.
  • Maak de waaier schoon.
  • Ensure pump is fully submerged.
  • Neem contact op met de klantenservice.

Specificaties

MerkBeckett
Modelnummer7218510
Maximale stroomsnelheid1250 GPH (20.83 gallons per minuut)
Maximale hefhoogte14.8 voet
Wattage50 Watt
Deeltage115 Volt
Frequentie60Hz
EnergiebronElektrische kabel
Snoerlengte15 voet
Productafmetingen (L x B x H)6.4" x 3.8" x 5.3"
Artikelgewicht4.3 pond
MateriaalCopper 20%, Epoxy 18%, Plastic 47%, Steel 15%
Compatibiliteit van slangen1 inch binnendiameter
VeiligheidscertificeringUL-vermeld
Comparison chart for Beckett pump models

Image: Comparison chart detailing specifications for various Beckett pump models, including the 1250 GPH (FC1200/FC1250) model.

Garantie-informatie

Beckett Corporation products are manufactured to high-quality standards. For specific warranty details, including duration and coverage, please refer to the documentation included with your purchase or visit the official Beckett Corporation webwebsite. Bewaar uw aankoopbewijs voor garantieclaims.

Klantenservice

If you have any questions, require technical assistance, or need to report an issue with your Beckett 1250 GPH Submersible Water Pump, please contact Beckett Corporation customer service.

For the most current contact information, please visit the official Beckett Corporation webRaadpleeg de website of de verpakkingsmaterialen.

Wanneer u contact opneemt met de klantenservice, houd dan uw modelnummer (7218510) en aankoopdatum bij de hand.

© 2024 Beckett Corporation. Alle rechten voorbehouden.

Ask a question about this manual