MARS67915

MARS 67915 Vervangende ontsteker voor oven: Installatie- en bedieningshandleiding

Model: 67915 | Merk: MARS

1. Inleiding

This manual provides essential information for the safe and correct installation, operation, and maintenance of the MARS 67915 Furnace Replacement Ignitor. This hot surface ignitor is designed to replace various original equipment manufacturer (OEM) ignitors in residential and commercial furnace systems. Please read this manual thoroughly before attempting any installation or service.

2. Veiligheidsinformatie

WAARSCHUWING: Onjuiste installatie, afstelling, wijziging, service of onderhoud kan materiële schade, letsel of overlijden veroorzaken. Lees de installatie-, bedienings- en onderhoudsinstructies zorgvuldig door voordat u deze apparatuur installeert of onderhoudt.

  • Always disconnect electrical power to the furnace at the main service panel. Close the manual gas shut-off valve to the furnace.
  • Turn off the gas supply to the furnace before performing any service to prevent gas leaks or explosions.
  • Hot surface ignitors are fragile. Handle with extreme care to avoid breakage. Do not touch the black ignitor surface with bare hands, as oils can reduce its lifespan.
  • De installatie mag uitsluitend worden uitgevoerd door een gekwalificeerde servicemonteur.
  • Ensure all wiring connections are secure and correct according to the furnace manufacturer's specifications.

3. Product voorbijview en functies

The MARS 67915 is a high-quality hot surface ignitor designed for reliable ignition in various furnace applications. It features a durable construction and is engineered to meet or exceed OEM specifications.

MARS 67915 Furnace Replacement Ignitor

Figuur 1: MARS 67915 Furnace Replacement Ignitor. This image displays the ignitor unit, which consists of a U-shaped black heating element attached to a ceramic base, with two brown wires and multiple white wires extending from the base, bundled together and terminating in a white connector.

Belangrijkste kenmerken:

  • Hot Surface Igniter technology for efficient and reliable ignition.
  • Equipped with 36-inch leads and a connector for versatile installation.
  • Direct replacement for numerous OEM ignitor models.

4. Compatibiliteit

The MARS 67915 ignitor is designed as a direct replacement for the following models:

  • Amstrong: 38322B001
  • Clare: C-238, C-242
  • DMO: 20834, 26789
  • Dornback: 271W
  • Rheem: 62-22441-01
  • Trane: 340039P01, IGN23
  • Uni-Line: 41-238, 41-242, 41-402
  • White Rodgers: 767A-371
  • Williamson: 09050

It is also used in specific Clare and ICP Equipment Models including: HEHE100S, HFHF100S, HEHF100, HEHF100S, HEHF100B, HEHF50, HEHF50B, HEHF80, HEHF80B, HEMB100, HEMB100B, HEMB110, HEMB110B, HEMB120, HEMB120B, HEMB130, HEMB130B, HEMB40, HEMB40B, HEMB50, HEMB50B, HEMB60, HEMB60B, HEMB70, HEMB70B, HEMB80, HEMB80B, HEMB90, HEMB90B.

Always verify compatibility with your specific furnace model and manufacturer's instructions before replacement.

5. Installatie-instructies

BELANGRIJK: Installation should only be performed by a qualified HVAC technician. Failure to follow these instructions can result in property damage, personal injury, or death.

  1. Veiligheid voorop: Schakel alle elektrische stroom naar de verwarmingseenheid uit via het hoofdverdeelpaneel. Sluit de handmatige gasafsluiter van de verwarmingseenheid.
  2. Toegang tot Ignitor: Locate and remove the furnace access panel(s) to expose the burner assembly and ignitor.
  3. Disconnect Old Ignitor: Carefully disconnect the wiring harness from the old ignitor. Note the routing of the wires.
  4. Oude ontsteker verwijderen: Unscrew or unclip the old ignitor from its mounting bracket. Handle it gently as it may be fragile.
  5. Montage inspecteren: Examine the mounting bracket for any damage or corrosion. Clean if necessary.
  6. Nieuwe Ignitor installeren: Carefully mount the new MARS 67915 ignitor onto the bracket using the original hardware or suitable replacements. Ensure it is securely fastened and positioned correctly according to the furnace manufacturer's specifications. Avoid touching the black ignitor element.
  7. Bedrading aansluiten: Connect the new ignitor's wiring harness to the furnace control board or existing wiring, ensuring a secure and correct connection. The MARS 67915 comes with 36-inch leads and a connector for direct replacement.
  8. Beveiligde panelen: Replace all furnace access panels securely.
  9. Stroom- en gasvoorziening herstellen: Open the manual gas shut-off valve. Restore electrical power to the furnace.
  10. Testbewerking: Initiate a call for heat at the thermostat and observe the furnace's ignition sequence to ensure the new ignitor glows and ignites the gas burner properly.

6. Werkingsprincipe

The MARS 67915 is a hot surface ignitor. When the furnace calls for heat, the control board sends voltage to the ignitor, causing its silicon carbide element to heat up rapidly to a very high temperature (typically over 1800°F or 980°C). Once the ignitor reaches its optimal temperature, the gas valve opens, allowing gas to flow over the hot ignitor, which then ignites the gas. After successful ignition, the ignitor typically de-energizes, and the flame sensor confirms the presence of a flame.

7. Onderhoud

The MARS 67915 ignitor is a sealed component and does not require routine user maintenance. However, regular professional furnace maintenance is recommended to ensure optimal performance and longevity of all furnace components, including the ignitor.

  • During annual furnace inspections, a qualified technician should visually inspect the ignitor for cracks, discoloration, or signs of wear.
  • Ensure the area around the ignitor and burner assembly is free from dust, debris, and obstructions.

8. Probleemoplossing

If your furnace is not igniting, and you suspect the ignitor, consider the following common issues. Always ensure safety precautions are followed before any inspection.

  • Ignitor Not Glowing:
    • Check for power to the furnace.
    • Verify wiring connections to the ignitor are secure.
    • The ignitor itself may be faulty or broken. A qualified technician can test its resistance.
  • Ignitor Glows but No Ignition:
    • Check if the gas supply to the furnace is open.
    • Ensure the ignitor is positioned correctly to ignite the gas stream.
    • There might be an issue with the gas valve or furnace control board.
    • The ignitor may not be reaching sufficient temperature to ignite the gas.
  • Furnace Cycles On and Off Rapidly: This could indicate a problem with the flame sensor, which works in conjunction with the ignitor.

For complex issues, it is highly recommended to contact a certified HVAC professional.

9. Specificaties

Fabrikant:MARS
Onderdeelnummer:67915
Artikelgewicht:1 pond
Kleur:Multicolor (referring to components)
Hoeveelheid artikelpakket:1
Leidt:36 inches with connector
ASIN:B00CD5ZPA0
Datum eerste beschikbaarheid:3 juni 2013

10. Garantie en ondersteuning

Specific warranty details for the MARS 67915 ignitor are typically provided at the point of purchase or can be obtained directly from the manufacturer, MARS. Please retain your proof of purchase for warranty claims.

For technical support, product inquiries, or warranty service, please contact MARS customer service or your authorized MARS dealer.

© 2024 MARS. Alle rechten voorbehouden. De informatie in deze handleiding kan zonder voorafgaande kennisgeving worden gewijzigd.

This manual is for informational purposes only. Always consult with a qualified professional for installation and service.

Gerelateerde documenten - 67915

Preview MARS HVAC/R Service- en Installatiecatalogus
Explore the comprehensive MARS catalog for HVAC/R service and installation products. Find essential components like air conditioner mounting brackets, condenser pads, vent kits, disconnect boxes, and more, designed for professional installation and reliable performance.
Preview MARS 2025 Aanbevolen Producten Gids: Motoren, Componenten, Service & Installatie
Ontdek de uitgebreide MARS 2025-productengids, die een overzicht biedt van de beste producten.asinEen breed assortiment motoren, componenten en service- en installatieproducten voor de HVAC/R-markt. Ontdek toonaangevende merken en innovatieve oplossingen.
Preview MARS SGF80S120D5S1A Single-Stage Onderdelenlijst voor gasovens met meerdere standen
Officiële onderdelenlijst voor de MARS SGF80S120D5S1A Single-Stage Multi-Position Gasoven. Dit document beschrijft de componenten, onderdeelnamen en aantallen voor de SE-serie 80% AFUE-oven.
Preview MARS: Onderdelen ontdekken: Handleiding voor het vervangen van HVAC/R-onderdelen
Een uitgebreide handleiding van MARS met een voorgestelde startvoorraad voor groothandels die de markt voor HVAC/R-vervangingsonderdelen, motoren en service-/installatieproducten betreden. Inclusief productcategorieën, artikelnummers en beschrijvingen.
Preview MARS 24 (MW) Water-naar-Water-serie: Installatie-, bedienings- en onderhoudshandleiding
Uitgebreide handleiding voor de MARS 24 (MW) watergekoelde serie, met informatie over installatie, bediening en onderhoud voor commerciële toepassingen. Bevat modelaanduidingen, veiligheidswaarschuwingen, onderhoud van het koelsysteem, technische specificaties en probleemoplossing.
Preview MARS Ceiling Cassette Replacement Parts List and Exploded View
Uitgebreide onderdelenlijst en exploded view view diagrams for MARS Comfort Aire Century Ceiling Cassette air conditioning units, including models B-VHP09CA-1, B-VHP12CA-1, B-VHP18CA-1, and B-VHP24CA-1.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.