AEMC 3711
AEMC Model 3711 Clamp-Gebruikershandleiding voor de aardingsweerstandsmeter
Model: 3711
Invoering
The AEMC Model 3711 is a portable clamp-on ground resistance tester designed for measuring electrical ground rod and grid resistance in multi-grounded systems. This instrument offers a non-intrusive method for testing without the need for auxiliary rods or disconnecting the ground system. It also measures leakage, neutral, and phase currents, providing a comprehensive solution for electrical system analysis.
Veiligheidsinformatie
WAARSCHUWING: Always read and understand all safety instructions before operating this instrument. Failure to do so may result in serious injury or death.
- This instrument is rated CAT III, indicating its suitability for measurements in building installations.
- Adhere to all local and national safety codes and regulations.
- Do not use the instrument if it appears damaged or is operating abnormally.
- Zorg ervoor dat het batterijcompartiment goed gesloten is voordat u het apparaat gebruikt.
- Avoid contact with live circuits during measurement.
- The instrument is double-insulated for enhanced safety.
Wat zit er in de doos?
Controleer bij het uitpakken of alle artikelen aanwezig zijn:
- AEMC Ground Resistance Tester Model 3711
- Calibration Check Loop, 25Ω
- Harde draagtas
- 9V Alkalinebatterij
- Gebruikershandleiding (dit document)
Product voorbijview

Image: The AEMC Model 3711 Clamp-On Ground Resistance Tester. This image displays the device with its red clamp jaws open, a black body, and a green digital display showing "9.8 Ω". Control buttons are visible below the display.
The AEMC Model 3711 features an ergonomic design for one-handed operation. Its robust polycarbonate construction ensures durability for outdoor use. Key components include:
- Clamp Kaken: 1.25" opening to accommodate ground rods and cables up to 1000kcmil.
- LCD-scherm: Digital readout for resistance and current measurements.
- Bedieningsknoppen: For power, data hold, and mode selection.
- Batterijcompartiment: Located at the rear for a 9V battery.
Installatie en batterij-installatie
- Open het klepje van het batterijcompartiment aan de achterkant van het instrument.
- Insert the supplied 9V Alkaline battery, observing correct polarity.
- Sluit het batterijklepje goed.
- Press the "ON" button to power on the device. The display should illuminate.
Gebruiksaanwijzing
Ground Resistance Measurement
- Power on the AEMC 3711.
- Open de clamp klembekken door de ontgrendelingshendel in te drukken.
- Plaats de clamp around the ground conductor or rod to be tested, ensuring the jaws are fully closed.
- The instrument will automatically measure and display the ground resistance in Ohms (Ω).
- For stable readings, allow approximately one second for the measurement to settle.
- To hold the current reading on the display, press the "HOLD" button. Press again to release.
Stroommeting
- Power on the AEMC 3711.
- Open de clamp kaken.
- Plaats de clamp around the conductor carrying the current to be measured (leakage, neutral, or phase current). Ensure the jaws are fully closed.
- The instrument will automatically measure and display the current in Amperes (A) of milliAmperes (mA).
- The current measurement function provides direct readings for leakage current flowing to ground or circulating in ground loops (down to 1mA) and neutral/phase currents (up to 30A RMS).
Onderhoud en kalibratie
Schoonmaak
Reinig het instrument met een zachte, damp doek. Gebruik geen schurende reinigingsmiddelen of oplosmiddelen.
Batterij vervangen
When the low battery indicator appears on the display, replace the 9V battery as described in the "Setup and Battery Installation" section.
Kalibratiecontrole
Use the supplied 25Ω calibration check loop to verify the instrument's accuracy periodically. Clamp the tester around the loop; the reading should be approximately 25Ω. If the reading deviates significantly, contact AEMC customer support for service.
Opslag
Store the instrument in its hard carrying case in a dry, cool environment when not in use. Remove the battery if storing for extended periods.
Probleemoplossing
- No Display/Instrument Not Powering On: Controleer de batterijinstallatie en zorg ervoor dat de batterij voldoende is opgeladen. Vervang de batterij indien nodig.
- Onstabiele metingen: Zorg ervoor dat de clamp jaws are fully closed around the conductor. Verify there is no excessive electrical noise in the environment.
- "OL" of Overbelastingsindicatie: The measured value exceeds the instrument's range. Ensure the correct measurement function is selected or the circuit parameters are within the device's limits.
- Onjuiste metingen: Perform a calibration check using the 25Ω loop. If the issue persists, contact technical support.
Specificaties
| Parameter | Waarde |
|---|---|
| Aardingsweerstandsbereik | Autoranging 0.01 to 1200Ω |
| Huidig meetbereik | Autoranging 1mA to 30.00A RMS |
| Resistance Measuring Frequency | 2403Hz |
| Current Measuring Frequency | 47 tot 800 Hz |
| Accuracy (Resistance) | ±2% reading ±0.02Ω (up to 25% of reading for 600-1200Ω) |
| Bedrijfstemperatuur | -10 tot 55°C (14 tot 131°F) |
| Energiebron | 9V batterij (inbegrepen) |
| Gewicht | 1 kg (2.2 lbs) |
| Afmetingen (H x B x D) | 235 x 100 x 55mm (9.25 x 3.94 x 2.17 inch) |
| Kaakopening | 1.25 inch |
| Veiligheidsclassificaties | EN 61010, CAT III, UL approved, CE marked |
Garantie en ondersteuning
For warranty information, technical support, or service inquiries, please refer to the official AEMC Instruments webwebsite of neem contact op met hun klantenservice. Bewaar uw aankoopbewijs voor garantieclaims.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.